Weber 5000 Gas Grill User Manual


 
33
ƽWARNING: If there is a leak at connections a or b,
retighten the fitting with a wrench and recheck for
leaks with soap and water solution.
If a leak persists after retightening the fitting, turn
OFF the gas. DO NO
T OPERATE THE BARBECUE.
Contact your dealer.
c) Side burner hose to side burner connection.
Figure 5 (c).
d) Valves to manifold connections. Figure 5 (d).
e) Hose to quick disconnect connection. Figure 5 (e).
ƽWARNING: If there is a leak at connections c, d or
e, turn OFF the gas. DO NO
T OPERATE THE
BARBECUE. Contact your dealer.
When leak checks are complete, turn gas supply OFF at
the source and rinse connections with water.
Annual Maintenance
After a period of nonuse we recommend that you
perform the following maintenance procedures
f
or your safety.
ƽWARNING: Check hose before each use of
barbecue for nicks, cracking, abrasions or cuts. If
the hose is found to be damaged in any way, do not
use the barbecue. Replace using only Weber
authorized replacement hose. Order from Weber-
Stephen Products Co., Customer Service Center or
authorized dealer.
Inspect the burners for correct flame pattern. Clean
if necessary, following the procedures outlined in
the "General Maintenance" section of this manual.
Check all gas fittings for leaks.
ƽWARNING: You should check for gas leaks every
time you disconnect and reconnect a gas fitting.
You will need: a soap and water solution and a rag or
brush to apply it.
Make sure main burners are in the OFF position.
Make sure side burner is OFF. Remove valve control
knob and screws. Remove enamel top.
Put the FlameCheck button on the FlameCheck valve.
To perform leak checks: turn on gas supply. Push the
FlameCheck button down and hold down until leak
checking is complete. This will allow gas to fill the hose
and manifold.
ƽWARNING: Do
not ignite burners while
leak checking.
Check for leaks by wetting the connections with the
soap and water solution and watching for bubbles. If
bubbles form or if a bubble grows there is a leak.
Note - Since some leak test solutions, including soap
and water, may be slightly corrosive, all connections
should be rinsed with water after checking for leaks.
Check:
a) Hose to manifold connection. Figure 5 (a).
b) Manifold to side burner hose connection.
Figure 5 (b).
ƽ DANGER ƽ
Do not use an open flame to check for
gas leaks. Be sure there are no sparks or
open flames in the area while you check for
leaks. This will result in a fire or explosion
which can cause serious bodily injury or
death, and damage to property.
Figure 5
(a)
(b)
(c)
(d)
(e)
Inspection and Cleaning of the Weber
Spider Stopper Guards
To inspect the Spider Stopper Guards, remove the
control panel and look to see if they have dust or dirt on
their outside surfaces. If they do, brush off the outside
surface of the Spider Stopper Guards with a soft bristle
brush (an old toothbrush for example). Check that there
are no gaps in the Spider Stopper Guards’ seams or in
the fit around the burners or valves. (See Section
"General Maintenance".)