INSTALLATION INSTRUCTIONS
,167$//$7,215(48,5(0(176$1'5(*8/$7,216
The appliance must be installed by a competent person in accordance with the current Gas Safety (Installation and Use)
Regulations or the rules in force and in accordance with the manufacturers instructions. Failure to do so could lead to
prosecution.
The following are the relevant Codes of Practice and British Standards.
The Building Regulations issued by the Department of the Environment.
The Building Standards (Scotland)(Consolidation) Regulations issued by the Scottish Development Department.
BS 8303 1994 BS 5440 Pt1 1990 & Pt2 1989 BS 7566 Pts 1-4 1992
BS 1251 1987 BS 5871 Pt3 1991
BS 6891 1988 BS 6461 Pt1 1984
Important Notes
The fire place, chimney or flue must be sound and conform to the requirements of BS 83O3 1994 & BS 6461 Part 1 1984.
The effective flue height must be a minimum of 3 metres and should be a 225mm x 225mm brick, stone or a lined flue with
a minimum diameter of 175mm. Any permanent flue restrictions must be removed, and any variable dampers locked fully
open or removed. The flue must be swept prior to installation, unless new.
Care should be taken to prevent any damage being caused to surrounding soft furnishings or decor e.g. many embossed vinyl
wall coverings may become discoloured if located too close to the appliance. Clearances required for combustible shelves
are shown on page 4.
A hearth must always be provided to project forward of the trim a minimum of 300mm and a minimum of 150mm either
side of the fire opening. The hearth must be a minimum thickness of 12mm with a perimeter height of 50mm to deter
combustible materials, carpets etc, being placed on the hearth. The area under the firebox must have a minimum
non-combustible thickness of 25mm. In most installations a back panel will be required, this will need a minimum fire
resistance rating of Class O (100
O
C).
7(&+1, &$/'$ 7$
Height 560mm overall size of Box
Width 410mm overall size of Box
Depth 265mm overall size of Box
Height of Trim 605mm
Width of Trim 505mm
Overall Depth inc Front & Fret using (MACH 11) 340m
Maximum heat input (HIGH) (GROSS) 6.95 kW, 23,700 Btu/h
Minimum heat input (LOW) (GROSS) 3.6 kW, 12,300 Btu/h
Supply pressure (cold) 20 mbar +/- 1 mbar
Injector marking Cat. 046/19/196/79M
Pilot OP Oxy/Pilot NG 9022
Gas valve Concentric TESA 3058/S
Gas Connection 8mm O/D Tube
&217(176&+(&./,67
(See pages 14 & 15 for identification)
VENT BOX ASSEMBLY C/W: Burner assembly, and trim.
1 Simulated coal front
Coal support shelf
10 Large and 15 Small Coals.
Fitting kit
Installation & Users Instructions.