NEC NDA-30016-003 Turkey Fryer User Manual


 
NDA-30016 Revision 3.0 Page 9
Roamer Installation Guide Application Configuration
Step 5: User-Defined Parameters
Make the following additional parameter entries through the UserDefined
command on the APM Configuration Entry screen:
Parameter Entry Description
User Defined #1 3 The number of the Roamer D
term
function key LED. This number
must correspond to the function
key assigned to Roamer at the
NEAX MAT. For more
information, see Chapter 4, MAT
Assignments on page 15.
User Defined #2 0 The default Route Restriction
Class value.
User Defined #3 Y Y(es), implement the Name
Display feature; N (o), do not
implement the Name Display
feature and only display phone
numbers.
User Defined #4 R The way the privilege level is
determined when there is more
than one user assigned to a D
term
,
using the following characters:
H = Highest Priority level
among assigned users.
L = Lowest priority level
among assigned users.
R = Most recently added user
privilege level.
User Defined #5 Y Y(es). Roamer is to reset all
logical numbers to their home
numbers at the designated Reset
Time
N(o). Roamer is not to reset the
logical numbers daily. (See User
Defined #6.)
User Defined #6 3:00 The Reset Time on a 24-hour
clock at which all logical numbers
are reset daily to their home
numbers. This entry is valid only
if User Defined #5 is set to Y(es).