Napoleon Fireplaces BGD42P Outdoor Fireplace User Manual


 
21
W415-0381 / E / 02.09.06
against the
threaded stud (B)
at the other end.
The blower must
be able to be po-
sitioned entirely onto
the pad.
Tilt the blower onto its
side. Slide it past the
controls and into the
clip (C). Secure to the
threaded stud using
the lock washer and
wing nut provided.
Ensure that the blower does not touch the fireplace base
or the firebox.
Attach the connectors
from the black and white
wires to the thermodisc
and secure the
thermodisc bracket to the
securing stud at the bot-
tom left of the unit using
a lock washer and wing
nut. Ensure that the
thermodisc touches the
firebox wall.
Attach the connectors
from the black and red
wires to the blower.
Attach and secure the vari-
able speed switch using
the nut provided. Plug the
harness cord into the re-
ceptacle.
The wire harness provided in this kit is a universal
harness. When installed, ensure that any excess
wire is contained, preventing it from making con-
tact with moving or hot objects.
Because the blower is thermally activated, when
turned on, it will automatically start approximately
10 minutes after lighting the fireplace and will run
for approximately 30-45 minutes after the fire-
place has been turned off. Use of the fan increases
the output of heat.
Drywall dust will penetrate into the blower bear-
ings, causing irreparable damage. Care must be
taken to prevent drywall dust from coming into
contact with the blower or its compartment. Any
damage resulting from this condition is not cov-
ered by the warranty policy.
ELECTRICAL INSTALLATION TO BE DONE BY A QUALI-
FIED INSTALLER and must be connected and grounded
in accordance with local codes. In the absence of local
codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE
in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the
United States.
To safely install the fan, turn off the electricity first.
If the fireplace was not previously equipped with a fan:
route a grounded 2-wire, 60hz power cable to the junction
box. At this point, it must be strain relieved and insulated.
The wire harness provided in this kit is a universal har-
ness. When installed, ensure that any excess wire is con-
tained, preventing it from making contact with moving or
hot objects.
To ease installation of the fan, remove the hinge screen
and valve control door (lower louvres) from the base of the
fireplace.
FIGURE 41
FIGURE 45
FIGURE 46
FIGURE 42
CHARCOAL EMBERS
VERMICULITE
CHARCOAL LUMPS
OPTIONAL BLOWER INSTALLATION
bracket allow ease of
adjustment when
attaching the blower.
For a quiet running
blower, do not allow the
assembly to sit on the
firebox base.
Slide the vibration reducing pad (A) into the clip (C) and up
C
A
B
FIGURE 43
FIGURE 44