Napoleon Grills GSS36N Outdoor Fireplace User Manual


 
11
W415-0369 / E / 02.16.07
Main burner goes
out; pilot stays on.
Pilot ame is not large enough
or not engul ng the thermo-
pile
- turn up pilot ame.
- replace pilot assembly.
Thermopile shorting - clean thermopile connection to the valve. Reconnect.
- replace thermopile / valve.
Remote wall switch wire is too
long; too much resistance in
the system.
- shorten wire to correct length or wire gauge.
Faulty thermostat or switch.
- replace.
Pilot will not light. - check if pilot can be lit by a match
- check that the wire is connected to the push button ignitor.
- check if the push button ignitor needs tightening.
- replace the wire if the wire insulation is broken or frayed.
- replace the electrode if the ceramic insulator is cracked or broken.
- replace the push button ignitor.
No spark at pilot burner
- ll the tank.Out of propane gas
Spark gap is incorrect
- spark gap should be 0.150” to 0.175” (5/32” to 11/64” approx.) from
the electrode tip and the pilot burner. To ensure proper electrode loca-
tion, tighten securing nut ( nger tight plus 1/4 turn).
No gas at the pilot burner
- check that the manual valve is turned on.
- check the pilot ori ce for blockage.
- replace the valve.
- call the gas distributor.
Pilot goes out when
the gas knob is re-
leased.
The gas valve has
an interlock device
which will not al-
low the pilot burn-
er to be lit until
the thermocouple
has cooled. Allow
approximately 60
seconds for the
thermocouple to
cool.
System is not correctly
purged.
- purge the gas line.
Out of propane gas. - ll the tank.
Pilot flame is not large
enough
- turn up the pilot ame.
- gently twist the pilot head to improve the ame pattern around the
thermocouple.
Pilot ame is not engul ng the
thermocouple.
Thermocouple shorting /
faulty.
- loosen and tighten thermocouple.
- clean thermocouple and valve connection.
- replace thermocouple.
- replace valve.
Faulty valve.
- replace.
Pilot burning; no
gas to main burner;
gas knob is on ‘HI’;
wall switch / ther-
mostat is on.
Themostat or switch is de-
fective.
- connect a jumper wire across the wall switch terminals; if main burner
lights, replace switch / thermostat.
Main burner ori ce is plugged. - remove stoppage in ori ce.
Faulty valve.
- replace.
Wall switch wiring is defec-
tive.
- disconnect the switch wires & connect a jumper wire across terminals
1 & 3; if the main burner lights, check the wires for defects and / or
replace wires.
TROUBLE SHOOTING GUIDE
SYMPTOM PROBLEM TEST SOLUTION