KitchenAid KBNU367T Gas Grill User Manual


 
10
The 20 lb LP gas fuel tank must be mounted and secured.
1. Open the 20 lb LP gas fuel tank drawer.
2. Place the 20 lb LP gas fuel tank bottom collar into the
mounting hole in the tank tray.
3. Tighten the locking screw against the bottom collar of the
20 lb LP gas fuel tank to secure.
4. Slide tank drawer back into the cabinet.
Local LP Gas Supply
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition. The qualified
LP gas technician shall provide the LP gas supply to the selected
grill location in accordance with the National Fuel Gas Code,
ANSI Z223.1/NFPA 54 and local codes.
Natural Gas Conversion
Conversion must be made by a qualified gas technician. The
qualified Natural gas technician shall provide the Natural gas
supply to the selected grill location in accordance with the
National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition,
and local codes. For conversion to Natural gas, the Natural gas
conversion kit must be used.
IMPORTANT: The gas installation must conform with local
codes, or in the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1/NFPA 54 - latest edition.
To convert to Natural gas, the Natural Gas Conversion Kit Part
Number W10118098 must be used. Follow instructions included
with the kit.
Gas Connection Requirements
Style 2 - Built-In Outdoor Grills
Natural Gas
Built-in grill models are equipped for use with Natural gas. They
are design-certified by CSA International for LP (propane or
butane) gases with appropriate conversion.
Built-in models are set for Natural gas use and have a pressure
regulator with ½" female pipe threads.
The supply line shall be equipped with an approved shutoff valve.
This valve should be located in the same area as the grill and
should be in a location that allows ease of opening and closing.
A.Locking screw
B.Mounting hole
C.Bottom collar
A.Grill gas pipe
B.New ANSI Z21.54 certified gray hose
C.Rear of grill
D.To local LP gas supply
A
B
C
A
B
C
D
A.Grill gas pipe
B.New ANSI Z21.54 certified gray hose
C.Rear of grill
D.To Natural gas supply
A.Grill gas pipe
B.New CSA International approved
“outdoor” flexible gas supply line
C.Rear of grill
D.To Natural gas supply
A
B
C
D
A
B
C
D