Hearth and Home Technologies HST-42D Fire Pit User Manual


 
11
3
3
Maintainance and Service
Figure 3.1 Chimney & Termination Cap Cleaning
A. Disposal of Ashes
Frequency: When they reach bottom of grate
By: Homeowner
WARNING! Risk of Fire! Ashes could contain hot em-
bers.
Place ashes in a metal container with a tight- tting lid.
The closed container should be placed on a
noncombustible oor or on the ground, well away from
all combustible materials, pending nal disposal.
If the ashes are disposed of by burial in soil or otherwise
locally dispersed, they should be retained in the closed
container until all cinders have thoroughly cooled.
B. Chimney Inspection/Cleaning
Frequency: At least twice a year during heating season
or as recommended by a certi ed chimney sweep
By: Certi ed chimney sweep
WARNING! Risk of Fire! Ignited creosote is extremely
HOT. Prevent creosote buildup.
Refer to Figure 3.1 to remove/reinstall termination caps.
Creosote - Formation and Need for Removal
When wood is burned slowly, it produces tar and other
organic vapors, which combine with expelled moisture to
form creosote. The creosote vapors condense in the rela-
tively cool chimney ue of a slow-burning re. As a result,
creosote residue accumulates on the ue lining. When
ignited this creosote makes an extremely hot re.
WARNING! Risk of Fire! A chimney re can permanently
damage your chimney system and nearby structures.
In the event of a chimney re, Hearth & Home Technolo-
gies Inc. recommends
replacement of the chimney, and
inspection of the adjacent structure to the provisions of
NFPA Level III inspection criteria.
The chimney shall be inspected at least twice a year
during the heating season to determine when a creosote
buildup has occurred.
When creosote has accumulated it shall be removed to
reduce the risk of a chimney re.
Heat & Glo • HST-42D • 27177 • Rev AB • 11/08
Chimney
Remove 4 screws
and lift top pan off.
Cap
Slip
Section
ST375
Square
Termination Cap
Cap
Remove screws,
lift top cover.
Top Cover
TR344/TR342
Round
Termination Cap
Chase
Cap
1. Remove the 4 screws.
2. Remove the screen.
3. Remove the baffle.
TS345/TS345P
Square
Termination Caps
TCT375
Terra Cotta
Termination Cap
Remove 2 screws from
the front and back and
lift the top off.