Hearth and Home Technologies CASTLEWOOD 42 Outdoor Fireplace User Manual


 
Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev C • 4/11
28
C. Clear Space Near the Fireplace
Combustible materials must not be stored on the hearth ex-
tension. Outdoor room furnishings such as chairs or other
combustibles must be at least 4 ft (1.22 m) from the open
front of the  replace.
D. Firescreen
A  rescreen is always provided to control sparks. It must be
closed whenever the  replace is in use. Glass doors or  re-
screens must not be used to hold burning material inside the
replace. Only those glass doors speci cally tested and list-
ed for use with the speci c  replace model should be used.
Screens should be closed when the glass doors are closed.
Fire Risk
Close  rescreen when burning  replace.
Do not use  rescreen or glass doors to
hold burning material in  replace.
Firescreen controls sparks.
Glass may break or burning material may
roll out.
WARNING
E. Glass Doors
Most ef cient  replace operation using glass doors is with
the doors open. When the doors are open the screen must
be closed. Only Hearth & Home Technologies glass doors
may be used. See Figure 10.1 for proper glass door opera-
tion.
FULLY OPEN
CORRECT
PARTLY CLOSED
INCORRECT
PARTLY OPEN
INCORRECT
FULLY CLOSED
CORRECT
Fire Risk
Smoke Risk
Doors must be fully opened or fully closed
when operating  replace.
Partially opened doors may draw  ame, smoke
or heat from  replace.
WARNING
Figure 10.1 Proper Operating Positions of Bi-fold Doors
THERE IS NOT A FLUE DAMPER, THEREFORE UNIT
CANNOT BE INSTALLED INDOORS.