Hearth and Home Technologies CASTLEWOOD 42 Outdoor Fireplace User Manual


 
Outdoor Lifestyles by Hearth & Home Technologies Inc. • 4070-300 Rev C • 4/11
10
2 in./51 mm
minimum air
space clearance
to the enclosure.
Use only noncombustible
material below the top of
the top standoffs.
28-3/8 in.
721 cm
74-1/2 in.
1892 cm
53- 7/8 in.
1368 cm
C. Sidewalls/Surrounds
Locate adjacent combustible sidewalls a minimum of 24 in. (610 mm) from replace opening.
Mantle leg, surround, stub wall, whether combustible or non-combustible, may be constructed as shown in Figure 3.4.
D. Frame the Fireplace
Figure 3.4 shows typical framing using combustible materials (2x4 lumber shown). Cooling air hoods required If total struc-
ture is non-combustible, cooling air hoods are not necessary.
Observe all required air space clearances to combustible materials as shown in Figure 3.5.
18 1/2 in.
[470 mm]
19 3/4 in.
[500 mm]
4 in.
[102 mm]
50° angle
39° angle
24 in.
[610 mm]
BRICK
FRONT
FLUSH
FRONT
24 in.
[610 mm]
22 3/8 in.
[568 mm]
52-7/8 in.
(1343 mm)
42 in.
[1067 mm]
Note: Grid depicts 1 inch squares.
Figure 3.4 Mantel Leg, Surround or Wall Projection (acceptable on both sides of opening)
Figure 3.5 Framing the Fireplace