Fisher & Paykel BGB36 Gas Grill User Manual


 
10
BGB 48 BQAR = 1378 mm
BGB 48 BQR = 1382 mm
BGB 36 BQAR = 1082 mm
(with rotisserie motor mounted)
BGB 48 Models = 1216 mm
BGB 36 Models = 911 mm
(without rotisserie motor mounted)
rotisserie
motor
616 mm
267 mm
673 mm
grill
exhaust
76 mm (to non-combustible
construction / minimum
hood clearance)
254 mm
648 mm
559 mm
562 mm
51 mm
81 mm
centre of gas inlet
centre of gas inlet
Bottom of
support ange
Min. 115mm
FIG. 8
INSTALLATION
LOCATING GRILL/BUILTIN CLEARANCES
Clearances to Non-Combustible Construction*
Clearances to Non-Combustible Construction*:
A minimum of 76 mm clearance from the back of the grill to non-combustible construction is required for the
purpose of allowing the hood to open fully. It is desirable to allow at least 153 mm rear and side clearance to
non-combustible construction above the cooking surface for counter space. If you’ll be using the rotisserie op-
tion, the space is essential for motor and skewer clearance. The grill can be placed directly adjacent to non-com-
bustible construction below the cooking surface. (Fig. 8)
WARNING!
Failure to maintain required clearances creates a fire hazard that may result in property damage or serious personal
injury. We recommend installing the Grill as far away from combustible surfaces as possible.
WARNING!
The BGB Grill is designed to function in an open area. Recommended minimum clearances should be maintained
to all surfaces (combustible and noncombustible) for optimum performance. Noncombustible material within the
minimum clearance area could result in discoloration or deterioration.
WARNING!
If a noncombustible material such as stucco is covering a combustible material such as wood, the minimum clear-
ance distance needs to be held to the wood. The presence of a noncombustible material inside the clearance zone
does not eliminate the minimum clearance zone to combustible material.
* DEFINITION OF NONCOMBUSTIBLE MATERIAL - Material which is not capable of being ignited and burned, such as
materials consisting entirely of, or a combination of, steel, iron, brick tile, concrete, slate, and plaster.
Clearances to Combustible Construction**:
Minimum of 310 mm from the sides and rear of grill must be maintained to adjacent vertical combustible con-
struction, above the counter top level. You should take in account that there is a large volume of heat, and smoke
will exhaust from the rear of the grill. This may discolour or damage unprotected areas (Fig. 04). Do not install
under unprotected combustible construction without using a fire safe ventilation system.
A 310 mm minimum clearance must be maintained under the counter top to combustible construction. The clear-
ance can be modified by a use of an insulated jacket.