Enviro 828 BV. FS. Fire Pit User Manual


 
4. DECIDING WHERE TO LOCATE YOUR FREESTANDING STOVE
1. The stove should be located out of traffic and away from furniture and draperies.
2. This stove should have sufficient access for its safe operation and maintenance.
3. Locate a position where the flue system of the stove can be properly installed without damaging the integrity
of the building. e.g. cutting wall or ceiling joists.
4. The stove can be installed on any wooden or non-combustible flat surface extending the full width and depth
of the appliance.
5. Check stove and flue system clearance requirements.
6. Locate the stove where it can be accessed by a gas supply line.
7. Locate the stove in a large and open room that is centrally located in the house. This will optimize heat
circulation and comfort.
8. If the stove is equipped with an optional convection fan, ensure that an electrical outlet is within 6ft. (1.8m)
of the stove.
9. These stoves can be installed in bedrooms.
10. The flow of combustion and ventilation air must not be obstructed.
PRIMARY INSTALLATION
A= Clearance above grade, verandah, porch, deck,
or [balcony (*12 inches (30cm) minimum]
B= Clearance to window or door that may be
opened [*12 inches (30cm) minimum]
C= Clearance to permanently closed window
[minimum 12 inches (30cm) recommended
to prevent condensation on window]
D= Vertical clearance to ventilated soffit located
above the terminal within a horizontal
distance of 2 feet (60cm) from the center-
line of the terminal [24 inches ( 60cm) minimum]
E= Clearance to unventilated soffit [18 inches
(45cm) minimum]
F= Clearance to outside corner [12 inches
minimum]
G= Clearance to inside corner [12 inches minimum]
H= *Not to be installed above a meter/regulator
assembly within 3 feet (90cm) horizontally
from the center-line of the regulator
I= Clearance to service regulator vent outlet [*6
feet (1.8m) minimum]
J= Clearance to non-mechanical air supply inlet to
building or the combustion air inlet to any
other appliance [12 inches (30cm) minimum]
K= Clearance to a mechanical air supply inlet [*6
feet (1.8m) minimum]
L= *** Clearance above paved side-walk or paved
driveway located on public property [*7 feet
(2.1m) minimum]
M= Clearance under verandah, porch, deck, or
balcony [*24 inches (60cm) minimum **]
*** A vent shall not terminate directly above a side-walk or paved driveway which is located between two single family dwellings and serves
both dwelling
** Only permitted if verandah. Porch, deck, or balcony, is fully open on a minimum of 2 sides beneath the floor
5