Enviro 25BV Fire Pit User Manual


 
3.VENTING FIREPLACE INSERTS
WARNING: Operation of this heater when not connected to a properly installed and
maintained venting system can result in carbon monoxide (CO) poisoning and possible death.
The Envirogas ACCENT 25 may be installed and vented into any solid fuel fireplace that has been installed in accordance with
the National, Provincial/State and local building codes and has been constructed of non-combustible materials.
An approved full length chimney liner and rain cap must be used. A throat connector or flashing must be installed, to ensure a
tight seal, top performance, safety and efficiency. Carefully follow the manufacturers instructions which accompany the
chimney liner kit.
Install sealed throat connector or flashing to prevent leakage of room air up through
chimney.
Measure the height of the chimney beforehand and purchase the appropriate kit.
Never attempt to over stretch a flexible liner to accommodate the height of the
chimney.
Make sure that all chimney clean outs are tightly fitting and will not permit air to leak
into the chimney.
The chimney must be clean, in good working order and constructed out of non-
combustible materials.
Any flue damper must be removed or blocked permanently in the open position.
Remove the vent collar plate from the top of the insert and connect it securely with
sheet metal screws and/or hose clamps. Check for any tears in the liner at this
point. (See also Assembly and Installation Instructions section 3.
)
IMPORTANT: The screws that hold the vent collar plate in it's approved position
must be installed.
PREPARATION FOR INSTALLATION
Remove the packaging from the appliance and surround panels, check to make sure there is no damage.
Carefully check the glass door. Do not use the unit if it is damaged. In the event damage is found please report it
to both the courier and your dealer as soon as possible.
Carefully clean the fireplace and flue before installing the stove. Failure to do so may result in fumes or dirt being
blown into the room and may cause a fire leading to death or serious injury.
6