Desa (V)CD36TPE Outdoor Fireplace User Manual


 
www.desatech.com
116035-01E32
8. Push in gas control knob all the way and hold.
Immediately light the pilot by repeatedly de-
pressingthepiezosparkignitoruntilaame
appears. Continue to hold for about one (1)
minute after the pilot is lit. Release gas control
knob and it will pop back. Pilot should remain
lit. If it goes out, repeat steps 5 through 8.
• If gas control knob does not pop up when
released, stop and immediately call your
service technician or gas supplier.
• If the pilot will not stay lit after several tries,
turn the gas control knob to “OFF” and call
your service technician or gas supplier.
9. Turnonallelectricpowertoreplace.
10. Turn gas control knob counterclockwise
to “ON”.
11. This valve is equipped with a HI/LO fea-
ture.Setreplaceinputasdesired.
12. Close lower louver panel.
TO TURN OFF GAS

1. Open lower louver panel.
2. Set the wall switch to the OFF position or
the HRC selector switch (when equipped)
to prevent draining the battery.
3. Turn off all electric power to the appliance
if service is to be performed.
4. Push in gas control knob slightly and turn
clockwise to “OFF”.
5. Close lower louver panel.

You may shut off the burners and keep the pilot
lit by doing one of the following:
1. Turn gas control knob clockwise to the
PILOT position.
2. Set the wall switch to the OFF position or
the HRC selector switch (when equipped)
to prevent draining the battery.
MANUAL LIGHTING

1. Remove glass door (see Removing/Replacing
Glass Door, page 29).
2. Follow steps 1 through 8 under Lighting In-
structions, page 31.
3. Depress gas control knob and light pilot
with match.
4. Keep gas control knob pressed in for 30 sec-
onds after lighting pilot. After 30 seconds,
release gas control knob. Follow steps 9
through 12 under Lighting Instructions.
5. Replace glass door (see Removing/Replacing
Glass Door, page 29).
OPTIONAL HAND-HELD
REMOTE OPERATION
Note: All remote control accessories must be
purchased separately (see Accessories, page
45). Follow instructions included with the
remote control.

-
Lighting
Instructions
Afterlighting,letpilotameburnforabout
one minute. Turn control knob to ON position.
Adjustameadjustmentknobanywherebe-
tween HI and LO. Slide the selector switch to
the REMOTE position (see Figure 61). Note:
The burner may light if hand-held remote was
on when selector switch was last turned off.
You can now turn the burner on and off with
the hand-held remote control unit.
IMPORTANT: Do not leave the selector switch
in the REMOTE or ON position when the pilot
is not lit. This will drain the battery.
O
F
F
P
I
L
O
T
L
O
I
H
ON
OFF
REMOTE
ON
OFF
O
N
Blower Control Knob
(Optional Accessory)
Variable Control
Knob
Selector Switch in
Remote Position
Gas Control Knob
in ON Position
Figure 61 - Setting the Selector Switch,
Gas Control Knob and Variable Control
Knob for Remote Operation

Hold the control button on the hand-held re-
mote until burner turns on. Hold the control
button again until burner turns off (see Figure
62, page 33).
OPERATING FIREPLACE
Continued