Desa (V)CD36TNE Outdoor Fireplace User Manual


 
www.desatech.com
116035-01E34
OPERATING FIREPLACE
Continued
OPERATING OPTIONAL
GWMT1 - WALL MOUNTED
THERMOSTAT
WARNING: Do not con-



LightthereplaceasinstructedinLighting
Instructions on page 31. Set wall thermostat to
desired temperature.
This thermostat has been electronically cali-
brated at the factory and requires no adjust-
ment or leveling.
Upon installation, the thermostat must be al-
lowed to stabilize at room temperature for a
minimum of 30 minutes for proper operation.
Toturnthereplaceoff,adjustthermostatto
the lowest setting and turn the gas control knob
back to PILOT. The pilot will remain lit.
IMPORTANT: To turn the pilot off, turn the
gas control knob on the heater to the OFF
position.
OPERATING OPTIONAL

Locate the blower controls by opening the lower
louverpanelonthereplace.Blowercontrols
are located on the right side of the switch
bracket to the left just inside the louver panel.
The BK manual blower and the BKT thermo-
statically-controlled blower have an ON setting
and an OFF setting. The blower will only run
when the switch is in the ON position. In the
OFF position, the blower will not operate.
Note for BKT Only: If you are using BKT
blower with optional thermostat (wall mounted
orremotecontrol)forthereplace,yourre-
place and blower will not turn on and off at the
sametime.Thereplacemayrunforseveral
minutes before the blower turns on. After the
heater modulates to the pilot position, the blow-
er will continue to run. The blower will shut off
afterthereboxtemperaturedecreases.
The blower helps distribute heated air from
thereplace.Periodicallycheckthelouversof
thereboxandremoveanydust,dirtorother
obstructionsthatwillhindertheowofair.
ELECTRONIC INGNITION
FOR YOUR SAFETY

WARNING: If you do not fol-
low these instructions exactly,
     
-

A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
totheoorbecausesomegasisheavierthan
airandwillsettleontheoor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not
use any phone in your building.
• Immediately call your gas supplier
from a neighbor's phone. Follow the gas
supplier's instructions.
C. Do not use this appliance if any part has
been under water. Immediately call a
qualiedservicetechniciantoinspectthe
appliance and to replace any part of the
control system and any gas control which
has been under water.
LIGHTING

1. STOP! Read the safety information
above.
2. Turnoffallelectricalpowertothereplace.
3. Turn wall switch to the OFF position.
4. Open lower louver panel.
5. Turn equipment shutoff valve clockwise
to the OFF position (see Figure 63). Do
not force.
Figure 63 -
Turning Equipment Shutoff Valve
to the OFF Position
Equipment
Shutoff Valve
Adjustment
Screw