Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
115603-01A
15
15
For more information, visit www.desatech.com
For more information, visit www.desatech.com
OUTSIDE AIR MECHANISM
The outside air handle is located at the right hand side of the fireplace
rear refractory (see Figure 33). Pull to close, push to open. Always
open the mechanism when starting a fire. This provides adequate
outside combustion air. Close the mechanism when not in use to
prevent cold air from entering the room. Periodically check you’re
outside air intake vent hood for any possible obstructions such as
snow, bushes, etc.
DAMPER MECHANISM
The damper control lever is located inside the fire chamber (see
Figure 33). Make sure lever is cool before handling. Pull down to
CLOSE, push up to OPEN. The damper must be open when lighting
a fire. Not doing so will cause smoke spillage into the room. When
the fireplace is not in use, close the damper to prevent down drafts
to enter the room.
Figure 33 - Damper Operation
GRATE
The grate is designed to provide you with the maximum solid fuel
capacity. Do not attempt to defeat its purpose. Doing so may cause
smoke spillage and a fire hazard. Do not overload the grate or
obstruct the required air space beneath it. Always keep ashes from
building up under the grate.
WARNING: RISK OF FIRE! Replace grate with
DESA model 3610ST-GR grate only.
Never obstruct the flow of combustion and ventilation air. Keep the
front of the fireplace clear of all obstacles and materials.
For further operating guidelines, instructions, and warranty infor-
mation not contained in this owner’s manual, contact your autho-
rized dealer.
WARNING: Children and adults should be alerted
to the hazards of high surface temperatures, and to
stay away to avoid burns or clothing ignition. Young
children should be carefully supervised when they
are in the same room as the fireplace.
OPERATING GUIDELINE AND MAINTENANCE INSTRUCTIONS
Damper Mechanism
Outside Air Mechanism
Grate
TECHNICAL SERVICE
OPERATING GUIDELINES
AND MAINTENANCE
INSTRUCTIONS
Continued
GRATE
OUTSIDE AIR
HANDLE
PULL TO CLOSE
PUSH TO OPEN
DAMPER CONTROL LEVER
PULL DOWN TO CLOSE
PUSH UP TO OPEN
TECHNICAL SERVICE
You may have further questions about installation, operation, or
troubleshooting. If so, contact DESA’s Technical Service Depart-
ment at 1-866-672-6040. When calling please have your model and
serial numbers of your heater ready.
You can also visit DESA’s technical services web site at
www.desatech.com.