Desa HDCFTP Outdoor Fireplace User Manual


 
www.desatech.com
111044-01F
20
OPERATING FIREPLACE
Continued
LIGHTING
INSTRUCTIONS
WARNING: You must operate
this fireplace with the fireplace
screen in place. Make sure fire
-
place screen is installed before
running fireplace.
NOTICE: During initial operation
of new fireplace, burning logs
will give off a paper-burning
smell. Orange flame will also be
present. Open window to vent
smell. Operate fireplace on HI
position to burn off odor. This
will only last a few hours.
1.
STOP! Read the safety information on
page 19.
2. Make sure equipment shutoff valve is fully
open.
3. Turn control knob clockwise
to the
OFF position.
4. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information above. If you donʼt smell
gas, go to the next step.
5. Turn control knob counterclockwise
to the PILOT position. Press
in control knob for five (5) seconds (see
Figure 30).
Note: You may be running this fireplace for
the first time after hooking up to gas sup
-
ply. If so, the control knob may need to be
pressed in for 30 seconds or more. This will
allow air to bleed from the gas system.
• If control knob does not pop up when
released, contact a qualified service person
or gas supplier for repairs.
6. With control knob pressed in, push down
and release ignitor button. This will light
pilot. The pilot is attached to the front of
burner. If needed, keep pressing ignitor
button until pilot lights.
Note: If pilot does not stay lit, refer to
Troubleshooting, page 23. Also contact a
qualified service person or gas supplier for
repairs. Until repairs are made, light pilot
with match. To light pilot with match, see
Manual Lighting Procedure, page 21.
7. Keep control knob pressed in for 30 seconds
after lighting pilot. After 30 seconds, release
control knob.
Note: If pilot goes out, repeat steps 3
through 7. This fireplace has a safety in
-
terlock system. Wait one (1) minute before
lighting pilot again.
8. Turn control knob counterclockwise
to desired heating level. The main
burner should light. Set control knob to any
heat level between HI and LO.
CAUTION: Do not try to ad-
just heating levels by using the
equipment shutoff valve.
Ignitor
Button
Figure 30 - Control Knob In The OFF
Position
Control
Knob
Thermocouple
Pilot Burner
Figure 31 - Pilot
Ignitor
Electrode
TO TURN OFF GAS
TO APPLIANCE
Shutting Off Fireplace
1. Turn control knob clockwise
to the
OFF position.
2. Turn off all electric power to the appliance
if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise
to the
PILOT position.