Installation must include an equipment shutoff valve, union, and
plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge
hook up. NPT tap must be upstream from heater (see Figures 30).
IMPORTANT:
Install equipment shutoff valve in an accessible
location. The equipment shutoff valve is for turning on or shutting
off the gas to the appliance.
Check your building codes for any special requirements for locating
equipment shutoff valve to fireplaces.
Apply pipe joint sealant lightly to male NPT threads. This will
prevent excess sealant from going into pipe. Excess sealant in pipe
could result in clogged fireplace valves.
WARNING: Use pipe joint sealant that is resistant
to liquid petroleum (LP) gas.
We recommend that you install a sediment trap in supply line as
shown in Figure 30. Locate sediment trap where it is within reach for
cleaning. Install in piping system between fuel supply and heater.
Locate sediment trap where trapped matter is not likely to freeze. A
sediment trap traps moisture and contaminants. This keeps them
from going into fireplace controls. If sediment trap is not installed
or is installed wrong, fireplace may not run properly.
NOTICE: Most building codes do not permit con-
cealed gas connections. A flexible gas line is pro-
vided to allow accessibility from the fireplace (see
Figure 31). The flexible gas supply line connection to
the equipment shutoff valve should be accessible.
CONNECTING FIREPLACE TO GAS SUPPLY
Installation Items Needed
Phillips screwdriver
sealant (resistant to propane/LP gas, not provided)
1. Remove screws that attach branch support to fireplace (see
Figure 31). Carefully lift up branch support and remove from
fireplace (see Figure 31).
Figure 31 - Removing Branch Support From Fireplace
(Thermostat-Controlled Model Shown)
Branch Support
Flexible Gas Line
INSTALLATION
Continued
INSTALLATION
Connecting To Gas Supply (Cont.)
Connecting Fireplace to Gas Supply
CAUTION: Use only new, black iron or steel pipe.
Internally-tinned copper tubing may be used in cer-
tain areas. Check your local codes. Use pipe of 1/2"
or greater diameter to allow proper gas volume to
fireplace. If pipe is too small, undue loss of volume
will occur.
* Purchase the optional CSA design-certified equipment shutoff valve from
your dealer. See Accessories, pages 38 and 39.
Figure 30 - Gas Connection
CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*
3"
Minimum
Approved Flexible
Gas Line
Pipe Nipple Cap Tee Joint
PROPANE/LP
From External
Regulator (11"
W.C.** to 14"
W.C. Pressure)
NATURAL
From Gas Meter
(5" W.C.** to 10.5"
W.C. Pressure)
Sediment Trap