Desa CDCFNRA Outdoor Fireplace User Manual


 
www.desatech.com
116658-01A
6
Figure 3 - Assembling Hood
Hood
Sheet Metal
Screws
Firebox
Top
Louver
AIR FOR COMBUSTION
AND VENTILATION
WARNING: This fireplace
shall not be installed in a con-
fined space or unusually tight
construction unless provisions
are provided for adequate com
-
bustion and ventilation air. Read
the following instructions to in
-
sure proper fresh air for this and
other fuel-burning appliances in
your home.
Todayʼs homes are built more energy efficient
than ever. New materials, increased insulation, and
new construction methods help reduce heat loss
in homes. Home owners weather strip and caulk
around windows and doors to keep the cold air out
and the warm air in. During heating months, home
owners want their homes as airtight as possible.
While it is good to make your home energy effi
-
cient, your home needs to breathe. Fresh air must
enter your home. All fuel-burning appliances need
fresh air for proper combustion and ventilation.
Exhaust fans, fireplaces, clothes dryers, and fuel
burning appliances draw air from the house to
operate. You must provide adequate fresh air for
these appliances. This will insure proper venting
of vented fuel-burning appliances.
PROVIDING ADEQUATE
VENTILATION
The following are excerpts from National Fuel
Gas Code, ANSI Z223.1/NFPA 54, Section 5.3,
Air for Combustion and Ventilation.
All spaces in homes fall into one of the three fol
-
lowing ventilation classifications:
1. Unusually Tight Construction
2. Unconfined Space
3. Confined Space
The information on pages 6 through 8 will help
you classify your space and provide adequate
ventilation.
Unusually Tight Construction
The air that leaks around doors and windows
may provide enough fresh air for combustion and
ventilation. However, in buildings of unusually
tight construction, you must provide additional
fresh air.
Unusually tight construction is defined as
construction where:
a. walls and ceilings exposed to the out
-
side atmosphere have a continuous
water vapor retarder with a rating of
one perm (6 x 10
-11
kg per pa-sec-m
2
) or
less with openings gasketed or sealed
and
b. weather stripping has been added on
openable windows and doors and
c. caulking or sealants are applied to
areas such as joints around window
and door frames, between sole plates
and floors, between wall-ceiling joints,
between wall panels, at penetrations
for plumbing, electrical, and gas lines,
and at other openings.
If your home meets all of these three
criteria, you must provide additional
fresh air. See Ventilation Air From
Outdoors, page 8.
If your home does not meet all of the three
criteria above, proceed to Determining
Fresh-Air Flow For Fireplace Location.
3. Locate four black phillips sheet metal screws
in hardware packet.
4. Slide hood between louver and firebox top and
align screw holes.
5. Insert screws as shown in Figure 3. Tighten
screws firmly.
HOOD ASSEMBLY
Continued