Desa CDCFNRA Outdoor Fireplace User Manual


 
www.desatech.com
116658-01A 27
Clean the pilot assembly also. A yellow tip on the
pilot flame indicates dust and dirt in the pilot as
-
sembly. There is a small pilot air inlet hole about
two inches from where the pilot flame comes out
of the pilot assembly (see Figures 48 or 49 depend-
ing on model). With the unit off, lightly blow air
through the air inlet hole. You may blow through a
drinking straw if compressed air is not available.
CLEANING AND
MAINTENANCE
Continued
Figure 48 - Pilot Inlet Air Hole
(Propane/LP Gas)
Pilot Assembly
Pilot Air Inlet Hole
Pilot Assembly
Pilot Air
Inlet Hole
Figure 49 - Pilot Inlet Air Hole
(Natural Gas)
WIRING DIAGRAM
Switch
Black
Auto
Off
On
Red
Red
White
Thermopile
Gas Control
TPTH TH
TPTH
TP
LOG SET
If you remove one-piece log set for cleaning,
refer to page 21, for placement instructions.
Replace log set if broken or chipped (dime-sized
or larger).
CABINET
Air Passageways
Use a vacuum cleaner or pressurized air to
clean.
Exterior
Use a soft cloth dampened with a mild soap
and water mixture. Wipe the cabinet to re-
move dust.