Desa M36, M42, VM36, VM42 Outdoor Fireplace User Manual


 
108795-01M
For more information, visit www.desatech.com
6
MANTEL CLEARANCES AND WALL DETAILS
A combustible mantle shelf maybe installed a maximum 12"
(229 mm) from the wall. Figures 5 and 6 show the minimum
allowable distances from various combustible mantle compo
-
nents in relation to the fireplace opening.
Spacer
3" (76mm)
1
1
/2"
(38mm) Max.
B
6" (152mm)
A
12"
(229mm)
Combustible
Materials
Header
Figure 5 - Mantel Clearances - Side View (Cross Section)
1
1
/
2
" (38 mm)
Max.
3" (76 mm)
Max.
6" (152 mm)
Max.
A
B
Outer Surround
Combustible
Material May
Be Used
TOP
VIEW
SAFE
ZONE
Perpendicular
Wall
Figure 6 - Side Clearances - Top View (Cross Section)
M36(B,H), M36P(B,H) M42(B,H), M42P(B,H)
VM36(B,H), VM36P(B,H) VM42(B,H), VM42P(B,H)
A 9" (229 mm) 6" (152 mm)
B 12" (305 mm) 9" (229 mm)
PRE-INSTALLATION
PREPARATION
Continued
M36(B,H), M36P(B,H) M42(B,H), M42P(B,H)
VM36(B,H), VM36P(B,H) VM42(B,H), VM42P(B,H)
A 14" (356 mm) 15" (381 mm)
B 8" (203 mm) 9" (229 mm)