Cal Flame LTR20091006 Outdoor Fireplace User Manual


 
Installation / Assembly
5
2009 Fireplaces and Firepits
LTR20091006, Rev. B
www.calspas.com
Installation must conform with local building and/or re codes, or in
the absence of local codes:
National Fuel Gas Code ANSI Z223.1 / INFPA 54 (for installation in
the United States)
CSA B149.1 Natural Gas and CAN/CGA-BIL/9-2, Propane Installa-
tion code (for installation in Canada).
Location
Place your repit or replace on a at and stable surface in an outdoor
location such as a patio deck. Do not locate the appliance where it can
get excessively wet or submerged in water.
When determining a suitable location, take into account concerns such
as exposure to wind, proximity to trafc paths, and windows that open
into the home.
Locate your repit or replace adjacent to the gas supply line (LP or
NG), preferably with the shortest gas line run possible.
Maintain the following clearances to combustible materials on all Cal
Flame replaces and re pits. Measure from the outside of the unit.
Sides (all around) 48 inches (1.2 m)
Top 72 inches (1.8 m)
Installation
Installation and service must be performed by a quali-
ed installer, service agency or your natural gas or liquid
propane (LP) gas provider.
Your Cal Flame repit or replace is designed and in-
tended for OUTDOOR USE ONLY in a well ventilated space
and must not be used inside a building, garage, or any other
enclosed area.