Cal Flame LTR20091006 Outdoor Fireplace User Manual


 
10
Installation / Assembly
2009 Fireplaces and Firepits
LTR20091006, Rev. B
www.calspas.com
Natural Gas
The appliance and its individual shut off valve must be disconnected
from the gas supply piping system during any pressure testing of the
system at test pressures in excess of ½ psig (3.5kPa).
This appliance must be isolated from the gas supply piping system by
closing its individual manual shut off valve during any pressure testing
of the gas supply piping system at test pressures equal to or less than
1/2 psig (3.5kPa).
Requirements
Always check the rating plate to make sure the gas
supply you are hooking up to is the gas type the
repit or replace is manufactured for.
The installation of this appliance must conform with lo-
cal codes or, in the absence of local codes, to the
national fuel gas code, ANSI Z223.1a-1998. Installation in Canada must
be in accordance with the standard CAN/CGA-B149.2, Propane Instal-
lation Code. Natural gas connection must be performed by a licensed
contractor or local gas company representative.
Ensure that the service supplying the repit or replace is tted with a
conveniently positioned shut off valve with easy access.
Installation
Connect the incoming gas supply line to the on/off gas valve of the
appliance. Make certain ALL gas connections are tight, turn the on/
off valve at the unit to the ‘on’ position and use soap and water to
test for leaks. Gas will be released at the burner for this duration. DO
NOT USE AN OPEN FLAME AND REMOVE BATTERY FROM IGNITER
BEFORE PERFORMING THIS TEST. An authorized gas appliance
installer must provide this installation service. Note that the
correct natural gas orice must also be installed prior to fuel line hook
up to maintain proper ame height and clean burn of fuel.