Cal Flame LTR20091006 Outdoor Fireplace User Manual


 
8
Installation / Assembly
2009 Fireplaces and Firepits
LTR20091006, Rev. B
www.calspas.com
2) Having at least two ventilation openings at cylinder valve level in
the side wall, equally sized, spaced at 180 degrees (3.14 rad), and
unobstructed. Make sure each opening has a total free area of not
less then ½ square inch per pound (3.2 sq. cm/kg) of stored fuel
capacity and not less then a total free area of 10 square inches
(64.5 sq. cm).
Ventilation openings need to be provided at oor level with a total
free area of ½ inch per pound (3.2 sq. cm/k) of stored fuel capacity
and not less than a total free area of 10 square inches if the ventila-
tion openings at oor level are in a side wall, make sure there are
at least two openings. The bottom of the openings shall be at oor
level and the upper edge no more than 5 inches (127 mm) above
the oor. The openings need to be equally sized, spaced at 180
degrees (3014 rad) and unobstructed.
Make sure every opening has minimum dimensions to permit the
entrance of a 1/8 inch (3.2mm) diameter rod.
There shall be a minimum clearance of 2 inches (40.8mm) between
the lower surface of the oor and the LP gas supply cylinder enclosure
and the ground.
Check the rating plate to make sure the gas supply you are hooking up
to is the gas type the repit or replace is manufactured for.
If you do not have an updated ller valve on your existing propane
tank, you will need to purchase one at your local hardware store, as
you will not be allowed to rell the tank at any lling station.
Use the pressure regulator and hose assembly supplied with LP mod-
els. Replacement pressure regulator and hose assemblies must be
those specied in this manual.
The 20 lb LP gas cylinder used must include a collar to protect the
cylinder valve.
Be certain to mount or set the 20 lb LP gas cylinder on a at surface
and restrain it to prevent it from tipping.