Problem Cause Solution
Burner will not light. Out of gas Rell LP gas cylinder. If natural model, turn
on gas at source.
Gas injector not inserted in venturi tube. Realign/engage gas injector with the ven-
turi tube.
Clogged gas injector. Remove gas injector from gas control as-
sembly and clean.
Obstruction in gas line. For propane models, ensure gas valve on
cylinder is OFF. Remove exible hose and
blow out any debris.
Spider webs in venturi tubes. Clean venturi tubes. See Maintenance
Section.
Misalignment of collector box and burner. Position electrode properly. Clean collector
box.
Dead battery. Replace with AA battery.
Inadequate grill temperature. Poor combustion. Adjust air shutter.
Misalignment of venturi tube and gas injec-
tor.
Realign/engage gas injector with the ven-
turi tube.
Inadequate gas pressure. Contact gas supplier for assistance.
Incorrect orice/valve setting. Refer to gas conversion instructions in this
manual.
Flames blow out. Cold grill. Preheat grill at least 15 minutes on HI with
the grill lid closed.
Misalignment of burner tube and gas injec-
tor.
Realign/engage gas injector with the
burner tube.
Poor combustion. Adjust air shutter.
Extreme wind. Turn or shield grill.
Yellow ames. Air shutter improperly set. Open air shutter.
Spider webs in venturi tubes. Clean venturi tubes. See Maintenance
Section.
Seasoning salts on burner. Clean by washing burner with mild deter-
gent.
Oil lm on burner. Allow burner to operate on HI for 10-15
minutes.
TROUBLESHOOTING