Weber Weber Gas Grill User Manual


 
10
Some LP tanks have differing top collar assembles. (The top collar is the metal
protective ring around the valve.) One series of tanks mount with the valve facing front
(1). The other tanks mount with the valve facing away from the fuel scale (2). Weber
recommends the use of cylinder manufacturer’s Manchester and Worthington, with a
47.6 lb water capacity. Other cylinders may be acceptable for use with the appliance
provided they are compatible with the appliance retention means (see illustrations).
The LP cylinder is installed inside the tank enclosure, on the tank scale (right side).
A) Loosen cylinder lock wing nut. Swing cylinder lock up (3).
B) Turn the LP cylinder so the opening of the valve is either to the front or rear of the
Weber
®
gas barbecue.
C) Lift tank up into position on the tank scale (4).
D) Swing the cylinder lock down. Tighten the wing nut.
Connect The Hose To The Cylinder
A) Remove the plastic dust cover from the valve.
B) Screw the regulator coupling onto the tank valve, clockwise, or to the right. Hand-
tighten only (5).
Note: This connection tightens clockwise and will not allow gas to flow unless the
connection is tight. The connection requires tightening by hand only.
m WARNING: Do not use a wrench to tighten the connection.
Using a wrench could damage the regulator coupling and
could cause a leak.
GAS INSTRUcTIoNS
1 2
3 3
5
4