Weber 425 Gas Grill User Manual


 
6
EACH HEAT ZONE OPERATES INDEPENDENTLY.
Summary lighting instructions are on the control panel.
Figure 1
ƽ
DANGER
Failure to open lid while igniting the
barbecue, or not waiting 5 minutes to
allow the gas to clear if the barbecue does
not light, may result in an explosive flame-
up which can cause serious bodily injury
or death.
High Medium Low Off
Crossover Ignition System
2
4
1
3
3) Make sure all burner control knobs are OFF. (Push
each burner control knob down and turn clockwise.)
ƽWARNING:The burner control knobs must be in the
OFF position before turning on the LP tank valve. If
they are not in the OFF position, when you turn on
the LP tank valve, the excess flow control will
activate, limiting the flow of gas from the LP tank. If
this should occur, turn OFF the LP tank valve and
burner control knobs and start over.
ƽ DANGER
When the excess flow control is
activated, a small amount of gas is still
flowing to the burners. After turning OFF
the tank and burner control knobs, wait at
least 5 minutes for the gas to clear before
attempting to light the barbecue. Failure
to do so may result in an explosive flame-
up which can cause serious bodily injury
or death.
LIGHTING
Note - The Crossover Ignition System ignites the Left
burner of each heat zone with a spark from the igniter
electrode inside the Gas Catcher Ignition Chamber.You
generate the energy for the spark by pushing the
Crossover Ignition Button until it clicks.
ƽWARNING: Check hose before each use of
barbecue for nicks, cracking, abrasions or cuts. If the
hose is found to be damaged in any way, do not use
the barbecue. Contact your dealer.
ƽWARNING:The storage space under the cooking
module is intended for storage of nonflammable
items only.
Crossover Ignition System
1) Open the lid. Figure 1.
2) Check that the fuel scale reads more than “E”.
Note - E = empty; F = full.
4) Turn the tank on by turning the tank valve
counterclockwise.
ƽWARNING: Do not lean over open barbecue. Keep
your face and body at least one foot away from the
matchlight hole when lighting the barbecue.
5) Select Heat Zone.
6) Push LEFT burner control knob down and turn to
START/HI.
7) Push the Crossover Ignition Button several times, so
it clicks each time.
8) Check that the burner is lit by looking through the
matchlight hole above the burner control knob.
ƽWARNING: If the burner does not light, turn the
LEFT burner control knob to OFF and wait 5 minutes
to let the gas clear before you try again or try to light
with a match.
9) After the LEFT burner is lit you can turn on the
RIGHT burner.
Note - Always light the LEFT burner first. The RIGHT
burner ignites from the LEFT burner.
TO EXTINGUISH
Turn gas supply OFF at the source, then push down
and turn each burner control knob clockwise to OFF.