Weber EP-310/320 Gas Grill User Manual


 
10
WWW.WEBER.COM
®
A1
a)
b)
A2
B1 B2
C1 C2
1.
2.
REMOVE CONTROL KNOBS & CONTROL PANEL FOR LEAK TESTING
You will need: Phillips screwdriver.
1) Remove control knobs.
2) Remove screw and washer from back of control panel with a Phillips screwdriver.
3) Tilt the back edge of the control panel up. Push in on the front edge to release
locking tabs. Carefully pull control panel away from frame.
4) Disconnect the igniter wires from the ignition module.
5) Replace control panel when leak check is completed.
GAS INSTRUCTIONS
You will need: LP cylinder, a soap-and-water solution and a rag or brush to apply it.
1) Connect LP cylinder.
Some regulators push ON to connect, and pull OFF to disconnect, others have a
nut that has a left-hand thread that connects to the cylinder valve. Follow speci c
regulator connection instructions.
A1) Screw regulator tting onto tank turning counter-clockwise. Position the
regulator so that the vent hole (a) faces down.
B1) Make sure regulator lever (b) is in the down/off position. Push regulator
down on tank valve until regulator snaps into position.
C1) Make sure regulator lever is in the off position. Slide the collar of the
regulator up (1). Push the regulator down onto the tank valve and
maintain pressure. Slide collar closed (2). If regulator does not lock,
repeat procedure.
2) Mix soap and water.
3) Turn on the cylinder valve.
A2) Turn cylinder valve clockwise.
B2) Move regulator lever counter-clockwise to the On position.
C2) Move regulator lever to the On position.
4) Check for leaks by wetting the tting with the soap-and-water solution and watching
for bubbles. If bubbles form, or if a bubble grows, there is a leak. If there is a leak,
turn off the gas and tighten the tting. Turn the gas back on and recheck with
the soap-and-water solution. If leak does not stop, contact the Customer Service
Representative in your area using the contact information on our website. Log onto
www.weber.com
®
.
5) When leak checking is complete, turn gas supply off at the source and rinse
connections with water.
ƽ DANGER
Do not use an open ame to check for gas leaks. Be sure
there are no sparks or open ames in the area while you
check for leaks. Sparks or ames will result in a re or
explosion that can cause serious bodily injury or death, and
damage to property.
CONNECTING THE LIQUID PROPANE CYLINDER
ƽ WARNING: Make sure that the LP cylinder valve is closed.
Close by turning valve clockwise.