Regency Wraps U41-LP3 Fire Pit User Manual


 
15
Regency U41-3 ULTIMATE Gas Fireplace Insert
OPERATING INSTRUCTIONS
OPERATING
INSTRUCTIONS
Before operating this appliance, proceed
through the following check list.
1) Read and understand these Instructions
before operating this appliance.
2) Check to see that all wiring is correct and
enclosed to prevent possible shock.
3) Check to ensure there are no gas leaks.
4) Make sure the three door glass pieces are
in place. Never operate the appliance with
any of the door glass removed or with the
door open. Do not strike the glass or slam
the door shut.
Warning: Do not operate appliance
with glass front removed, cracked
or broken. Replacement of the glass
should be done by a licensed or
qualifi ed service person.
5) Verify that all venting and the cap is unob-
structed.
6) Verify log placement. If the pilot cannot be
seen when lighting the unit - the logs or the
embers have been incorrectly positioned.
7) The unit should never to turned off and on
without a minimum of a 60 second wait.
8) When lighting the appliance, the inside of
the glass may fog up. This will burn off after
a few minutes of operation.
DO NOT BURN THE APPLIANCE WITH THE
DOOR OPEN.
LIGHTING
PROCEDURE
IMPORTANT: Gas cock knob cannot be
turned from "PILOT" to "OFF" unless it is
partially depressed.
1) Open the left side door when lighting the
pilot, but once the pilot is lit, DO NOT operate
the unit with the front glass door open.
2) Open the bottom louver assembly by turning
the wing nut and swinging the louvers out.
(See page 8 for diagram.)
3) If the control knob is in the "OFF" position
proceed to Step 5.
4) Push in gas control knob slightly and turn
clockwise to "OFF".
5) Wait fi ve minutes to allow gas, that may
have accumulated in the main burner
compartment, to escape. If you do smell
gas, follow the instructions on the front of
this manual. If you don't smell gas continue
on to the next step.
6) Turn the gas control counterclockwise to
"PILOT".
7) Push in control knob all the way and hold
in. Immediately push black button on spark
igniter until pilot lights. Continue to hold
the control knob in for approximately one
minute, then release the gas control knob.
The pilot fl ame should continue to burn. If
the pilot does not remain lit, repeat operation
allowing a longer period before releasing
gas control knob.
8) Turn gas control knob counterclockwise to
"ON".
9) Use rocker switch to operate main burn-
er.
10) Rotate the variable fl ame control to adjust
the fl ame height higher or lower.
11) Close the bottom louver assembly and
tighten the wingnut.
12) The door must be closed when operating
the unit.
Knob cannot be turned from "PILOT" to
"OFF" unless knob is pushed in slightly.
Do not force.
FIRST FIRE
The fi rst fi re in your stove is part of the paint
curing process. To ensure that the paint is
properly cured, it is recommended that you
burn your fi replace for at least four (4) hours
the fi rst time you use it with the fan on. When
fi rst operated, the unit will release an odour
caused by the curing of the paint, the burning
off of any oils remaining from manufacturing.
Smoke detectors in the house may go off at
this time. Open a few windows to ventilate the
room for a couple of hours.
The glass panel may require cleaning
after the unit has cooled down.
DO NOT ATTEMPT TO CLEAN THE
GLASS WHILE IT IS HOT.
Note: When the glass is cold and the appli-
ance is lit, it may cause condensation
and fog the glass. This condensation
is normal and will disappear in a few
minutes as the glass heats up.
DO NOT BURN THE APPLIANCE
WITHOUT THE GLASS FRONT IN
PLACE.
AUTOMATIC
CONVECTION FAN
OPERATION
The fan operates automatically, turn the knob
on the side of the faceplate to adjust to the
desired speed. The fan will turn on as the stove
comes up to operating temperature. After the
unit has been turned off and the unit cooled to
below a useful heat output range the fan will
shut off automatically.
SHUTDOWN
PROCEDURE
1) Use the rocker switch to turn off the main
burner.
2) Open the bottom louver assembly by turn-
ing the wing nut and swinging the louvers
out.
3) Push in the gas control knob slightly and
turn clockwise to "OFF". Do not force.
4) Disconnect all electric power to the appli-
ance if service is to be performed.