PGS A Series Gas Grill User Manual


 
PGS TROUBLESHOOTING GUIDE
No Flame Gas Shut off
Obstruction in Orifice(s)
Leak in Gas Train
No Gas in Tank or Not Connected to Gas Source
Low Flame Leak in Gas Train
Obstruction in Orifice(s) or venturi’s
Natural Gas valve only turned part way
Burner gasket plugging venturis.
High Flame Wrong Orifice Size for style Gas
Venturi Air shutter needs adjustment
Burner split
Flames out the Control Panel Spider webs in Venturi tubes see page 20
Valve knobs won’t turn Spider fire burnt out lubrication in valve
Lubrication dried out
Warped or bubbled Lower
Casting
Burner burnt out and emitting too much flame in
one area melting casting.
Burner left on for extended period of time
Wrong rock in casting causing build up of heat and
melting casting
Venturi tubes not lined up with gas valves
Stainless Steel rusting Grill placed near pool chemicals
Paint peeling Aluminum Base – sprinkler/animal urine/chemicals
Grill won’t light w/module No sound from Module – replace battery
Slight sound – cracked electrode or crack in wire -
After dark – look for spark
Electrode Missing from
Collector box
Electrode clip gave way and electrode fell out
Upper casting tipping or not
fitting
Holes for hinge pins are uneven, casting rear edge
bowed or uneven
22