Do not use abrasive cleaners to clean these parts. Buff
lightly with a clean dry cloth. Porcelain enamelled compo-
nents must be handled with care. The baked-on finish is
glasslike. If struck, it will chip! Touch-up paint is available
through your Napoleon dealer.
FIGURE 2
CARE OF GLASS, ENAMELLED AND PLATED PARTS
INSTALLATION
The glass is 3/16" ceramic glass available from your Na-
poleon dealer. DO NOT SUBSTITUTE MATERIALS. Clean
the glass after the first 10 hours of operation with a recom-
mended gas fireplace glass cleaner. Thereafter clean as
required. DO NOT CLEAN GLASS WHEN HOT! If the glass
is not kept clean permanent discolouration and / or blem-
ishes may result.
Line the chimney with a 4 inch diameter approved liner.
Pack insulation around the liner in the damper area to pre-
vent air flow from entering the chimney. Chimney installa-
tion must conform to both national and local code require-
ments. The liner must be continuous from the fireplace to
the chimney cap.
Remove the securing screw from the front of the dilution
plate. Push the dilution hood out of its securing clip and
attach the liner using 3 screws equally spaced. Move the
insert into the centre of the woodburning fireplace making
sure that the dilution draft hood inserts back into its secur-
ing clip. Level using the four levelling screws located front
and back on either side of the fireplace base.
Clean out ashes from the inside of the wood-burning fire-
place. Make sure that the chimney and wood-burning fire-
place are in a clean and sound condition and constructed
of non-combustible materials. If necessary have any repair
work done by a qualified person before installing the in-
sert. Remove the existing fireplace damper or lock into an
open position.
Using screws, attach the fireplace warning tag (W385-0199)
to the inside of the firebox of the fireplace into which the
insert is being installed.
The sheet-metal parts of the fireplace, in which the gas
fireplace insert is to be installed, must not be cut.
If the wood-burning factory-built fireplace has no gas
access hole(s) provided, an access hole of 1½ inch or
less may be drilled through the lower sides or bottom
of the fireplace in a proper workman like manner. This
access hole must be plugged with non-combustible in-
sulation after the gas supply line has been installed.
Ensure that existing chimney cleanouts fit properly.
The refractory, glass doors, screen rails, screen mesh
and log grates may be removed from the fireplace be-
fore installing the gas fireplace insert.
Smoke shelves, shields and baffles may be removed if
attached by mechanical fasteners.
The ventilation openings in the fireplace may be ob-
structed by the backer plates, aluminium trim etc. but
these parts are not to be applied so as to have an air-
tight seal.
WARNING: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIRE-
PLACE INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID
FUELS UNLESS ALL ORIGINAL PARTS HAVE BEEN REPLACED AND THE FIRE-
PLACE IS RE-APPROVED BY THE AUTHORITY HAVING JURISDICTION.
ATTENTION: CE FOYER A ETE CONVERTI AFIN D'ETRE UTILISE SEULEMENT COMME
FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU
TOUT AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES
ORIGINALES AIENT ETE REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE
NOUVEAU PAR LES AUTORITES AYANT JURIDICTION
.
W385-0199