Napoleon Grills PRESTIGE II 600 Gas Grill User Manual


 
4
www.napoleongrills.com
General Informaon
This Gas Barbecue Is Cered Under Canadian And American Naonal Standards, CAN/CGA-1.6-M95 AND
ANSI Z21.58 -1995 respecvely for Outdoor Gas Grills and should be installed to conform with local codes.
In absence of local codes, install to the current CAN1-B149.2 Propane Installaon Code in Canada or to the
Naonal Fuel Gas Code, ANSI Z223.1 in the United States.
If a rosserie motor is used, it must be electrically grounded in accordance with local codes or, in absence of
local codes, with the current CSA C22.1 Canadian Electrical Code in Canada or the Naonal Electrical Code,
ANSI/NFPA 70 in the United States.
California proposion 65: The burning of gas fuel creates by-products, some of which are on the list as
substances known by the State of California to cause cancer or reproducve harm. When cooking with gas,
always ensure adequate venlaon to the unit, to minimize exposure to such substances.
Propane Cylinder Specicaons
WARNING! If these instrucons are not followed exactly, a re causing death or serious injury may
occur.
A dented or rusty cylinder may be hazardous and should be checked by your propane supplier. Never use a
cylinder with a damaged valve. Use only a propane supply cylinder constructed and marked in accordance
with the specicaons for LP-gas cylinders of the Naonal Standard of Canada, CAN/CSA-b339, Cylinders,
Spheres and Tubes for Transportaon of Dangerous Goods; and Commission, as applicable or the Specica-
ons for LP-Gas Cylinders of the U.S. Department of Transportaon (D.O.T.). This appliance has been designed
for use with a 20 lb. (9.1 kg) size propane cylinder only (not supplied).
The propane cylinder must be provided with a cylinder connecon device compable with the connecon
for outdoor cooking appliances. The propane cylinder must be provided with a shut-o valve terminang in
a propane cylinder valve type QCC1, and a safety relief device having direct communicaon with the vapor
space of the cylinder. The cylinder supply system must be arranged for vapor withdrawal and the cylinder
shall include a collar to protect the cylinder valve. The cylinder shall incorporate a listed OPD (overll protec-
on device). Do not store a spare LP-gas cylinder under or near this appliance. Never ll the cylinder beyond
80 percent full.
Use only the pressure regulator and hose assembly provided with this barbecue. Replacement pressure regu-
lators and hose assemblies must be specied by the manufacturer. Do not store a spare propane cylinder on
the shelf beneath the barbecue.
The regulator supplies a pressure of 11 inches. water column to the gas grill and has a QCC1 type ng. Cyl-
inders to be used with this unit must be supplied with a QCC1 cylinder valve. A QCC1 cylinder has a posive
seang connecon, which will not allow gas ow unl a posive seal has been achieved. It is also equipped
with an excess ow device. In order to aain full ow to the grill, the valves must be in the o posion when
the cylinder valve is turned on.
Gas Hook-Up Instrucons
WARNING! A re will result if the gas supply hose makes contact with the underside of the grill or drip
pan.
Propane Cylinder Installaon: Set cylinder into hole in boom shelf.
Cylinder Connecon: Ensure the gas regulator hose is kink free. Remove the cap or plug from the cylinder fuel
valve. Insert the black QCC1 regulator nipple onto the QCC1 fuel valve. Hand ghten clockwise. Do not use
tools. Leak test all joints prior to using the grill. A leak test must be performed annually and each me a cylin-
der is hooked up or if a part of the gas system is replaced.
If this grill is to be connected directly to a house propane gas supply line, follow the instrucons for the natural
gas hook-up. Oponal side burners must also follow the natural gas hook-up instrucons. Note: The propane
tank heat shield is not required when the grill is connected to a xed fuel supply, as its sole funcon is to shield
the propane tank normally used with the grill. Ensure that the supply pressure is 11 inches water column.