41
www.napoleongrills.com
: This must be done before inial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignion. See Leak Tesng Dia-
gram for areas to check. Turn all burner controls to the o posion. Turn gas supply valve on.
Brush a half-and-half soluon of liquid soap and water onto all joints and connecons of the regulator, hose,
manifolds and valves.
Bubbles will indicate a gas leak. Either ghten the loose joint or have the part replaced with one recommended
by the Napoleon Customer Care department and have the grill inspected by a cered gas installer.
If the leak cannot be stopped, immediately shut o the gas supply, disconnect it, and have the grill inspected
by a cered gas installer or dealer. Do not use the grill unl the leak has been corrected.
: Il doit être fait avant la première ulisaon, annuellement et à chaque fois qu’une pièce du sys-
tème de gaz est remplacée ou réparée. Ne fumez pas et enlevez toutes sources d’allumage lorsque vous faites
ce test. Consultez le schéma de test de fuites pour voir les endroits à tester.
1 - Fermez tous les boutons des brûleurs. Ouvrez la soupape de la bonbonne.
2 - Appliquez une soluon de deux parts égales de savon liquide et d’eau sur tous les joints du régulateur, le
tuyau et ses raccords.
3 - Des bulles indiqueront une fuite de gaz. Resserrez le joint ou remplacez la pièce avec une autre recomman-
dée par le détaillant.
4 - Si la fuite ne peut être réparée, fermez l’alimentaon de gaz à la bonbonne, enlevez-la et faites inspecter
votre gril par votre fournisseur
de gaz ou détaillant. N’ulisez
pas l’appareil jusqu’à ce que la
fuite soit réparée.
5 - Fermez la soupape de la
bonbonne.