Meco Bonza Deluxe Series Charcoal Grill User Manual


 
STEP 13-LEAK TESTING (TO BE PERFORMED IN A WELL-VENTILATED AREA.)
Supplies Needed for a Leak Test
Clean paint brush, water, and dishwashing liquid
How to perform a leak test
WARNING! Never use an open flame to test for
gas leaks.
1) Mix one cup of water with one cup of dish washing
liquid.
2) Confirm that all control knobs on the control panel
are in the off position.
3) Remove control knobs and the three retaining screws at
the bottom of the control panel.
4) Remove front control panel cover.
5) Open valve on LP gas cylinder (Turn counter-
clockwise).
6) Check for leaks by brushing the soap solution on all
LP gas connections and fittings. Make sure you
generously brush the seven locations with the
soap solution, completely surrounding the connections
and fittings (See diagram below.)
7) If “growing” bubbles appear on any of the connection
points, then you have detected a gas leak. Immediately
close the LP cylinder valve.
A) If leak appears at either end of hose and regulator
assembly, retighten the connection at the leak,
but do not overtighten. (Note: Only hand tighten
at coupling nut) (See Step 12 of Assembly Ins
tructions) Repeat Leak Test.
B) If the leak is coming from the LP gas cylinder,
from the valves at the control knobs, or if the leak
cannot be stopped, do not use the grill. Call Custome
r Service at 1-800-251-7558.
8) Always turn off LP cylinder valve after performing a leak
test. (Turn clockwise to a full stop.)
9) If your LP gas grill has been in storage or has not been
used for a period of time, the burners should be
maintained. See Burner Maintenance in the Care and
Maintenance section of this manual.
· Perform a leak test before each use.
· Leak test must be performed in a well
ventilated area.
· Never perform a leak test on a grill while in use
or hot.
· If you detect a gas leak that cannot be corrected
by using the leak test procedures below, do not
use the LP gas grill.
· Never smoke or have an open flame near the
grill during a leak test.
· Insure Regulator Hose does not contact hot
metal surfaces.
21
3
4
3-THREADED FITTING
4-HOSE CONNECTION
2
1
1-MANIFOLD TUBE
2-REGULATOR HOSE FITTING
5, 6, 7 -GASKET SEAL
AROUND MANIFOLD TUBE
5
6