Majestic Appliances ODSHR42 Outdoor Fireplace User Manual


 
14
ODSHR Series
20002264
Stud
2 x 4 Finished
Header
Covered Wall
Ledge Bracket
Finished Wall
Noncombustible
Decorative Facing
Must be Sealed with
Noncombustible
Material
Surround
FP1167
Fig. 20 Facing on fireplace surround flush with finished wall.
Side Wall Protection
Adjacent combustible side walls that are within dimen-
sions shown in Figure 24 of fireplace opening must be
protected with Vermont Castings, Majestic Products
Wall Shield Model SP40 or a specifically built wall
shield described in Figure 22.
The special wall shield design described in Figure 22 is
an alternate method of adding protection to side walls
and can be used in place of the SP40 with the same
wall clearances specified for the SP40. Rt must =1.85
minimum.
Examples of wall shield insulation:
1. Manville - CERAFORM 126, K=.27,
1/2 inches thick
2. Majestic - EH2416, K = .458,
1 inch thick required.
40"
Min.
40" Min.
Decorative
Noncombustible
Rigid Covering
Noncombustible
Insulation
RT = 1.85 Min.
(Manville Ceraform 126
- 1/2" Thick or Majestic
EH2416 - 1" Thick)
Fig. 22 Noncombustible wall shield dimensions.
FP838
CAUTION:
Do Not Place
Finishing Material
Beyond These Edges
or Cover Air Inlets
Screen Rail
Hearth
FP1168
Fig. 21 Finishing front of fireplace.
MA81
Fig. 23 Combustible mantel clearances.
12"
1¹⁄₂"
Ref.
B
A
C
6" Min.
Combustible materials are
permitted within a shaded area
shown in Figure 24, titled
Minimum Wall Clearances.