Special offers from our partners!
Find Replacement BBQ Parts for 20,308 Models. Repair your BBQ today.
17
GAS CONVERSIONS
For Models Equipped for Use with a 20 lb LP gas Tank
NOTE: Models that are equipped for Natural gas require Gas Conversion Kit Part Number W10118099 for conversion to LP gas. Use
the conversion instructions included in the kit. See “Assistance or Service” section for information on ordering.
Tools and Parts for Gas Conversion
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools needed
Parts supplied
■ Brass connector
■ Convertible regulator 4" W.C. Natural, 11" W.C. LP
■ Natural gas orifices
IMPORTANT: Gas conversions must be done by a qualified
installer. Before proceeding with conversion, shut off the gas
supply to the appliance prior to disconnecting the electrical
power.
This kit is designed for use from sea level up to 2000 ft elevation.
For higher elevations contact KitchenAid at 1-800-422-1230 in
the U.S.A. or call 1-800-607-6777 in Canada.
Conversion to a Local LP Gas Supply
Installation of the regulator
1. Turn off the main gas supply valve.
2. Unplug side burner or disconnect power.
3. Disconnect 20 lb LP gas fuel tank (if present).
4. Turn off all burner control valves.
5. Remove rear cover and 2 screws.
6. Use adjustable wrench to remove LP hose regulator from
brass elbow. Use adjustable wrench to remove brass elbow.
7. Apply pipe sealant to the threads of the brass connector. Use
pipe thread sealant that is certified for use with LP gas.
8. Use adjustable wrench to install brass connector (supplied) to
manifold fitting.
NOTE: The arrow on the regulator must be pointing toward
the brass connector.
■ Phillips screwdriver
■ Pipe wrench
■ Adjustable wrench
■ 10 mm socket and wrench
or 10 mm nut driver
■ Thin flat-blade screwdriver
■ Pliers
■ Pipe thread sealant
certified for LP gas
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor”
gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 11” (28 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
A.Manifold
B.Brass elbow
C.Rear of side burner
D.Gas pressure regulator/hose assembly
B
A
C
D