Symptom Problem Solution
Smell Gas. Shut-off LP-Gas Cylinder Valve
at once. DO NOT use the
appliance until leak is sealed.
Leak detected at cylinder, regulator or Regulator tting loose. Tighten tting and “Leak Test”.
other connections.
Gas leak in hose/regulator or control See authorized service center.
valves.
Flame ashback beneath control panel. Venturi blocked. Remove burner, clean ventrui.
See “Venturi Tube”.
Burner will not light. Out of LP-Gas. Rell LP-Gas Cylinder.
Ignitor wire(s) not connected. Connect both main burner and
side burner electrode wires.
Ignitor electrode misaligned on burner. Realign electrodes.
Ignitor malfunction. Use “Manual Lighting” procedures.
Regulator is not fully connected to the Tighten the regulator hand-wheel.
cylinder valve.
Burner valve left open while cylinder Close burner and cylinder valves.
valve was opened causing excess Open cylinder valve slowly, then
ow device to activate. open burner valve to light.
A leak in the system causing the Leak test connections to
excess ow device to activate. determine loose tting. Tighten
tting. Leak test system.
Venturi blocked. Remove burner, clean venturi See
“Venturi Tubes”.
Venturi not aligned with valve orice. Realign venturi to orice. See
“Venturi Tubes”.
Orice blocked. Remove burner, clean orice with
a pin or ne wire. Do not attempt
to drill orice.
Hose is twisted. Straighten hose. Keep away from
bottom casting.
Decreasing heat, “popping sound”. Out of LP-Gas. Rell LP-Gas Cylinder.
Venturi blocked. Remove burner, clean venturi.
See “Venturi Tubes”.
Hot spots on cooking surface. Venturi blocked. Remove burner, clean venturi.
See “Venturi Tubes”
Troubleshooting