John Deere HR-BG5002, HR-BG5202, HR-BG6203 Gas Grill User Manual


 
Operator’s Manual 21
Symptom Problem Solution
Smell Gas. Shut-off LP-Gas Cylinder Valve
at once. DO NOT use the
appliance until leak is sealed.
Leak detected at cylinder, regulator or Regulator tting loose. Tighten tting and “Leak Test”.
other connections.
Gas leak in hose/regulator or control See authorized service center.
valves.
Flame ashback beneath control panel. Venturi blocked. Remove burner, clean ventrui.
See “Venturi Tube”.
Burner will not light. Out of LP-Gas. Rell LP-Gas Cylinder.
Ignitor wire(s) not connected. Connect both main burner and
side burner electrode wires.
Ignitor electrode misaligned on burner. Realign electrodes.
Ignitor malfunction. Use “Manual Lighting” procedures.
Regulator is not fully connected to the Tighten the regulator hand-wheel.
cylinder valve.
Burner valve left open while cylinder Close burner and cylinder valves.
valve was opened causing excess Open cylinder valve slowly, then
ow device to activate. open burner valve to light.
A leak in the system causing the Leak test connections to
excess ow device to activate. determine loose tting. Tighten
tting. Leak test system.
Venturi blocked. Remove burner, clean venturi See
“Venturi Tubes”.
Venturi not aligned with valve orice. Realign venturi to orice. See
“Venturi Tubes”.
Orice blocked. Remove burner, clean orice with
a pin or ne wire. Do not attempt
to drill orice.
Hose is twisted. Straighten hose. Keep away from
bottom casting.
Decreasing heat, “popping sound”. Out of LP-Gas. Rell LP-Gas Cylinder.
Venturi blocked. Remove burner, clean venturi.
See “Venturi Tubes”.
Hot spots on cooking surface. Venturi blocked. Remove burner, clean venturi.
See “Venturi Tubes”
Troubleshooting