WARNING! Always wear protecve gloves and safety glasses when cleaning your grill.
WARNING! To avoid the possibility of burns, maintenance should be done only when the grill is cool.
Avoid unprotected contact with hot surfaces. Ensure all burners are turned o. Clean grill in an area where
cleaning soluons will not harm decks, lawns, or paos. Do not use oven cleaner to clean any part of this
gas grill. Do not use a self-cleaning oven to clean cooking grids or any other parts of the gas grill.
Barbe
cue sauce and salt can be corrosive and will cause rapid deterioraon of the gas grill components
unless cleaned regularly.
Maintenance / Cleaning Instrucons
Note: Stainless steel tends to oxidize or stain in the presence of chlorides and suldes, parcularly in coastal
areas and other harsh environments, such as the warm, highly humid atmosphere around pools and hot tubs.
These stains could be perceived as rust, but can be easily removed or prevented. To provide stain prevenon
and removal, wash all stainless steel surfaces every 3-4 weeks or as oen as required with fresh water and/or
stainless steel cleaner.
We recommend this gas grill be thoroughly inspected and serviced annually by a qualied service person.
WARNING! Turn o the gas at the source and disconnect the unit before servicing. To avoid the
pos
sibility of burns, maintenance should be done only when the grill is cool. A leak test must be performed
annually and whenever any component of the gas train is replaced or gas smell is present.
Combuson Air Adjustment: (This must be done by a qualied gas installer.) The air shuer is factory set and
should not need adjusng under normal condions. Under extreme eld condions, adjustments might be
required. When the air shuer is adjusted correctly the ames will be dark blue, pped with light blue and
occasionally yellow.
With too lile air ow to the burner, the ames are lazy yellow and can produce soot.
With too much air ow, the ames li erracally and can cause dicules when lighng.
Adjusng the air shuer:
1. Remove cooking grids and sear plates and leave lid open.
2. Loosen air-shuer lock screw located at the mouth of the burner and open or close air shuer as required.
The normal opening sengs are:
Main Tube Burner Propane 5/32” (4mm)
Natural 5/32” (4mm)
*Infra-Red burners have no air adjustment.
3. Light the burners and set to high. Visually inspect burner ames. When the shuers are set correctly, turn
burners o, ghten locking screws, and replace removed parts. Ensure that the insect screens are installed.
Light Blue
Yellow Tipping
Dark Blue
Burner
Burner Port
Approximately
1/2” (13mm)