Heat & Glo LifeStyle 36DV Fire Pit User Manual


 
14
VENTING WITH ONE (1) 90° ELBOW
V (FT.) H (FT.)
1.5' MIN. (.457m) 2.5' MAX. (.762m)
2' MIN. (.609m) 3' MAX. (.912m)
2.5' MIN. (.762m) 6' MAX. (1.82m)
3.5' MIN. (1.06m) 9' MAX. (2.73m)
4.5' MIN. (1.37m) 12' MAX. (3.64m)
5.5' MIN. (1.67m) 15' MAX. (4.55m)
6.5' MIN. (1.98m) 18' MAX. (5.46m)
7.5' MIN. (2.28m) 21' MAX. (6.37m)
8.5' MIN. (2.59m) 24' MAX. (7.28m)
V = 40’ MAX. (12.2m)
V+H = 64’ MAX. (19.5m) H = 24' MAX. (7.28m)
Figure 11.
Venting with One 90° Elbow
NOTE: Must have a 12”
minimum vertical vent
before attaching a 90
o
elbow to the unit.
H
V
Figure 12. Venting with Two 90° Elbows
V FT. H + H
1
(FT.)
1.5' MIN. (.457m) 2.5´ MAX. (.762m)
2' MIN. (.609m) 3´ MAX. (.912m)
2.5' MIN. (.762m) 6´ MAX. (1.82m)
3.5' MIN. (1.06m) 9’ MAX. (2.73m)
4.5' MIN. (1.37m) 12´ MAX. (3.64m)
V+H+H
1
= 64' MAX.(19.5m)
H+H
1
= 24´ MAX. (7.3m)
V+V
1
+H
= 64' MAX.(19.5m)
VENTING WITH
TWO (2) 90
o
ELBOWS
H
V
V
V
1
H
H
1
H
V
NOTE: Must have a 12”
minimum vertical vent
before attaching a 90
o
elbow to the unit.