Desa (V)T36NA Outdoor Fireplace User Manual


 
www.desatech.com
111250-01E10
VENTING INSTALLATION
INSTRUCTIONS
Continued
WARNING: Do not recess


6.  Position the
horizontal vent cap in the center of the 7
3
/
4
"
round hole and attach to the exterior wall with
four wood screws provided. Before attaching
the vent cap to exterior wall, run a bead of
non-hardening mastic (pliable sealant) around
the outside edges to make a seal between it and
the outside wall. Note: The four wood screws
provided should be replaced with appropriate
fasteners for stucco, brick, concrete or other
types of sidings.
 For vinyl siding,
stucco or wood exteriors, a siding standoff may
be installed between the vent cap and exterior
wall. The siding standoff prevents excessive
heat from damaging the siding materials.
Siding material must be cut to accommodate
standoff. Bolt the vent cap to the standoff. Ap-
ply non-hardening mastic around outside edge
of standoff. Position the standoff/cap assembly
in the center of the 10" square hole and attach to
exterior wall with wood screws provided (see
Figure 11). The siding standoff must sit ush
against the exterior fascia material.
7.  Slide the wall
restop over the vent pipe before connecting
horizontal run to vent cap (see Figure 12).
8. Carefully move replace, with vent assembly
attached, toward wall and insert vent pipe
into horizontal termination. The pipe overlap
should be a minimum of 1
1
/
4
" (see Figure 13,
page 11).
9.  Slide wall
restop against interior wall surface and attach
with screws provided. See Figure 13, page 11,
for horizontal termination details.
10. Place replace into position and shim with
noncombustible material if needed. Nail or
screw side anges to framing to secure unit in
place. IMPORTANT: Make sure replace is
level before securing. If replace is not level
it will not work properly.
Figure 10 - Installing Horizontal Vent Cap
(Noncombustible Exterior)
Wood Screw
Vent Cap
Figure 11 - Installing Siding Standoff
(Combustible Exterior Wall)
Cut Siding Away to
Fit Standoff
Wood
Screw
Screws
Standoff
Vent
Cap
Apply Mastic
to All Four Sides
Vent Cap
(Horizontal
Termination)
Interior Wall
Surface
Wall
Firestop
Horizontal
Vent Pipe
Figure 12 - Connecting Vent Cap with
Horizontal Vent Pipe
Screw
Apply Mastic to
All Four Sides