Desa VM42P Outdoor Fireplace User Manual


 
www.desatech.com
108795-01N 19
OPERATING FIREPLACE
FOR YOUR SAFETY
READ BEFORE LIGHTING
WARNING: If you do not fol-
low these instructions exactly,
a fire or explosion may result
causing property damage, per
-
sonal injury or loss of life.
A. This appliance has a pilot which must be
lighted by hand. When lighting the pilot,
follow these instructions exactly.
B. BEFORE LIGHTING smell all around the
appliance area for gas. Be sure to smell next
to the floor because some gas is heavier than
air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not
use any phone in your building.
Immediately call your gas supplier
from a neighborʼs phone. Follow the
gas supplierʼs instructions.
If you cannot reach your gas supplier,
call the fire department.
C. Use only your hand to push in or turn the
gas control knob. Never use tools. If the
knob will not push in or turn by hand, donʼt
try to repair it, call a qualified service tech
-
nician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has
been under water. Immediately call a
qualified service technician to inspect the
appliance and to replace any part of the
control system and any gas control which
has been under water.
LIGHTING
INSTRUCTIONS
NOTICE: During initial operation
of new heater, burning logs will
give off a paper-burning smell.
Orange flame will also be pres-
ent. Open damper or window to
vent smell. This will only last a
few hours.
1. STOP! Read the safety information,
column 1.
2. Turn wall switch to the OFF position.
3. Turn off all electric power to the appliance.
4. Fully open glass doors if installed.
5. Remove front refractory brick access panel.
6. Turn gas control knob clockwise
to the OFF position (see Figure 39).
7. Wait five (5) minutes to clear out any gas.
Then smell for gas, including near the floor.
If you smell gas, STOP! Follow “B” in the
safety information above. If you donʼt smell
gas, go to the next step.
8. Turn control knob counterclockwise
to the PILOT position.
9. Push in the knob all the way and hold in.
Immediately light the pilot manually. Con
-
tinue to hold the control knob in for about
(1) minute after the pilot is lit. Release knob
and it will pop back up. Pilot should remain
lit. If it goes out, repeat steps 5 through 9.
If knob does not pop up when released,
stop and immediately call your service
technician or gas supplier.
If the pilot will not stay lit after sev
-
eral tries, turn the gas control knob to
“OFF” and call your service technician
or gas supplier.
10. Turn gas control knob counterclockwise
to “ON”. Knob can be turned to
“ON” only if the control knob is popped out.
11. Replace front refractory brick access panel.
12. Fully close glass doors if installed.
13. Turn on all electric power to the appliance.
P
I
L
O
T
ON
OFF
IN OUT
IN
Figure 39 - Control Knob in the PILOT
position
Position
Indicator
Gas Control
Knob
Pilot Adjustment
Screw