Desa LMFP33NR Outdoor Fireplace User Manual


 
www.desatech.com
111604-01E
11
Figure 12 - Inserting Fireplace Into
Cabinet Mantel
INSTALLATION
Continued
ACTUAL FRAMING
Height 32
3
/8" 33"
Front Width 34
5
/16" 35
1
/8"
Depth 16
11
/16" 17
3
/4"
BUILT-IN FIREPLACE
INSTALLATION
Built-in installation of this fireplace involves in-
stalling fireplace into a framed-in enclosure. This
makes the front of fireplace flush with wall. If in-
stalling a mantel above the fireplace, you must fol-
low the clearances shown in Figure 18, page 13.
Follow the instructions below to install the fire-
place in this manner.
35
1
/
8
"
17
3
/
4
"
33"
Figure 13 - Rough Opening for Installing
in Wall
39
3
/
8"
27
7
/
8"
55
5
/
8"
35
1
/
8"
WARNING: A qualified electri-
cian must connect electrical wir-
ing to duplex outlet for built-in
installation. Follow all local codes.
1. Frame in rough opening. Use dimensions shown
in Figure 13 for the rough opening. If installing
in a corner, use dimensions shown in Figure 14
for the rough opening. The height is 33" which
is the same as the wall opening above.
2. If using blower, install duplex outlet to the
right support bracket in the bottom of firebox
(see Figure 15).See Accessories, page 29. If
not using blower, go to step 7.
3. Route wires from electrical box through small-
est hole in outer casing using strain relief fit-
ting provided (see Figure 15).
4. Connect wires from the electrical box to du-
plex outlet. Match wire colors to those indi-
cated on duplex outlet. Be sure to connect
ground wire.
5. Install shield to end of right support bracket
and behind the firebox wrapper with 2 screws
provided (see Figure 16, page 12).
6. Plug blower cord into duplex outlet.
7. Replace bottom of firebox and reconnect re-
mote receiver module to valve.
Figure 14 - Rough Opening for Installing
in Corner
Blower
Support
Bracket
Cable from
Electrical Source
Duplex
Outlet
Screw
Blower
Power Cord
Strain
Relief
Fitting
Figure 15 - Connecting Duplex Outlet