Desa DVF34P Outdoor Fireplace User Manual


 
15
106424
OWNER’S MANUAL
VENTING
INSTALLATION
Continued
HIGH ALTITUDE
INSTALLATION
Your FMI direct-vent fireplace has been
AGA tested and approved for elevations
from 0-2000 feet and CGA certified for
elevations from 0-4500 feet.
When installing this fireplace at an elevation
above 2000 feet (in the USA), you may need
to decrease the input rating by changing the
existing burner orifice to a smaller size. Re-
duce input 4% for each 1000 feet above sea
level. Check with your local gas company for
proper orifice size identification.
When installing this fireplace at an eleva-
tion above 4500 feet (in Canada), check
with local authorities.
Consult your local gas company to help de-
termine the proper orifice for your location.
For assistance with any high altitude instal-
lation contact DESA International’s Tech-
nical Service Department at 1-800-DESA-
LOG (1-800-337-2564).
PARTS LISTS FOR VENTING
KITS AND COMPONENTS
FMI Rigid Venting
Number Description
FD30 30˚ Starter/Adapter (6 5/8" to 7")
6 per box
FD60 60˚ Starter/Adaptor (6 5/8" to 7")
6 per box
F7030 7" to 12" Adjustable pipe length
6 per box
D1031 7” to 12” Adjustable pipe length
1 per box
D3050 Vertical restrictor
6 per box
01806 Basic vertical kit
Adjustable flashing - storm collar,
vertical cap
01807 48" Pipe length
6 per box
01808 36" Pipe length
6 per box
01809 24" Pipe length
6 per box
01810 12" Pipe length
6 per box
01811 6" Pipe length
6 per box
01812 17" to 24" adjustable pipe length
6 per box
01813 45˚ Elbow
6 per box
01814 90˚ Elbow
6 per box
01817 Wall firestop
6 per box
01818 Adjustable flashing (0/12-8/12)
6 per box
01819 Steep pitch flashing (12/12
6 per box
01820 Vinyl/Stucco siding standoff
01821 Firestop plate
6 per box
01822 Vertical termination cap
01823 Horizontal round termination
cap
Number Description
01825 36" Snorkel termination
01826 14" Snorkel termination
01827 Termination/high
rise/horizontal
01828 Wall strap
6 per box
01829 Storm collar
6 per box
01797 Vertical round high wind
termination
01799 Horizontal square high wind
termination