Continental CBI 360-P Outdoor Fireplace User Manual


 
9
W415-0120 / E / 01.11.05
TURN OFF THE GAS AND ELECTRICAL POWER
BEFORE SERVICING THE FIREPLACE.
CAUTION: Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper and dan-
gerous operation. Verify proper operation after servicing.
This insert and its venting system should be inspected
before use and at least annually by a qualified service per-
son. The fireplace area must be kept clear and free of com-
bustible materials, gasoline or other flammable vapours
and liquids. The flow of combustion and ventilation air must
not be obstructed.
1. In order to properly clean the burner and pilot assembly,
remove the logs to expose both assemblies.
2. Keep the control compartment, logs, burner, air shutter
opening and the area surrounding the logs clean by vacu-
uming or brushing, at least once a year.
3. Check to see that all burner ports are burning. Clean out
any of the ports which may not be burning or are not burn-
ing properly.
4. Check to see that the pilot flame is large enough to
engulf the thermopile on one leg and reaches toward the
burner on the other leg.
5. Replace the cleaned logs.
6. Check to see that the main burner ignites completely on
all openings when the gas knob for the burner is turned
on. A 5 to 10 second total light-up period is satisfactory. If
ignition takes longer, consult your Continental dealer / dis-
tributor.
7. Check that the door gasketing is not broken or missing.
Replace if necessary.
MAINTENANCE
A This fireplace has a pilot which must be lit by hand
while following these instructions exactly.
B Before lighting, smell all around the fireplace area for
gas and next to the floor because some gas is heavier
than air and will settle on the floor.
C Use only your hand to push in or turn the gas control
knob. Never use tools. If the knob will not push in or
turn by hand, do not try to repair it. Call a qualified ser-
vice technician. Force or attempted repair may result in
a fire or explosion.
D Do not use this fireplace if any part has been under
water. Immediately call a qualified service technician
to inspect the unit and replace any part of the control
system and any gas control touched by water.
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbour's
phone. Follow the gas supplier's instructions.
If you cannot reach your gas supplier, call the fire de-
partment.
1.Stop! Read all the safety information above. When light-
ing and re-lighting, the gas knob cannot be turned from
"pilot" to "off" unless the knob is depressed.
2.Turn off all electrical power to the stove.
3.Turn the gas knob
clockwise to off.
4.Wait 5 minutes for any gas in the combustion chamber
to escape. Continue to the next step if you do NOT smell
any gas. If you smell gas, STOP! and follow the instruc-
tions in "What to do if You Smell Gas" listed above.
5.If the unit is equipped with a flame adjustment valve,
turn
clockwise to off.
6.Locate the pilot situated in front of the rear log.
7.Turn the gas knob counter-clockwise to "pilot"
position.
8.Depress and hold the gas knob while lighting the pilot
with the push button ignitor. Keep the knob fully depressed
for one (1) minute, then release. If the pilot does not con-
tinue to burn, repeat steps 3 through 7.
9.With the pilot lit, turn the gas knob counter-clock-
wise
to "on" position.
10.If your insert is equipped with a flame adjustment valve,
push and turn the knob to "high".
11.If your insert is equipped with a remote "on-off" switch,
the main burner may not come on when you turn the gas
valve to "on" or "high". The remote switch must be in the
"on" position as well to ignite the main burner.
12.Turn on all electrical power to the insert.
2.Push in gas control knob slightly and turn clock-
wise to off. DO NOT FORCE.
1.Turn off all electrical power to the unit if service is to be
performed.
FOR YOUR SAFETY READ BEFORE LIGHTING:
WHAT TO DO IF YOU SMELL GAS:
LIGHTING INSTRUCTIONS
TO TURN OFF GAS