Vermont Casting ODSHR42 Outdoor Fireplace User Manual


 
5
ODSHR Outdoor Woodburning Fireplace
20002264
FP554A
SH Series
1/28/99 djt
Chase Installation
Insulation methods shown are optional for cold climate, not a
requirement for unit operation or exterior installation .
FP554A
Fig. 4 Fireplace and chase parts identification.
Termination Cap
Storm Collar
Pan Flashing
Batt Insulation
(cut out around
firestop)
Firestop
Ceiling
Level
Draftstop
Ledge Bracket
Surround
Damper Control
Gas Line
Knockout
(both sides)
Screen
Grate
Firebox
Metal Safety
Strips (1,2 or 3)
Outside Air
Cover Plate
Gas Line Access
(both sides)
FP1001
fireplace setting
1/4/00 djt
NOTE: If the fireplace is a free-
standing unit, it must be located
a minimum of 10' (3 m) from the
opening of the firebox to a com-
bustible structure.
A minimum height of 6'4" (1.9 m)
measured from the base of the
firebox to the bottom of the termi-
nation cap is permitted.
10'
(3 m)
Min.
6'4" (1.9 m)
Min.
FP1001
Fig. 5 Freestanding installation.
Exterior Chase Installation
FP1641
exterior chase installation
9/06
Termination Cap
Storm Collar
Pan Flashing
Ledge
Bracket
Surround
Damper
Control
Gas Line
Knockout
(both
sides)
Screen
Grate
Firebox
Metal Safety
Strips (1,2 or 3)
Outside Air
Cover Plate
Gas Line Access
(both sides)
Interior sides
of chase
should be
weather proof
Exterior
Siding
Exterior
Siding
Interior Chase
Installation