Vermont Casting ODSHR42 Outdoor Fireplace User Manual


 
11
ODSHR Outdoor Woodburning Fireplace
20002264
Positioning, Safety Strips,
Securing the Fireplace
Slide fireplace into position.
Lift the fireplace front slightly and slide the metal safety
strips under front bottom edge about 1¹⁄₂" (38 mm),
allowing the remainder to extend in front of firebox.
Overlap strips at least 1/2" (13 mm) to provide a posi-
tive joint. (Flat safety strips are packed with fireplace.)
(Fig. 12)
Safety strips are used to ensure that any combustible
materials in front of the fireplace are protected even
though a noncombustible hearth extension is required.
If fireplace is to be elevated above the floor, a “Z”
shaped metal safety strip must be fabricated and used
to protect combustible surfaces in front of the fireplace.
This “Z” shaped safety strip is not provided but must be
fabricated of metal with each horizontal leg at least 1¹⁄₂"
(38 mm) wide and equal in length to the metal strips
provided with the fireplace.
NOTE: Safety strips are not required over noncombus-
tible floors where all supports at the base of the fire-
place are noncombustible.
Four (4) nailing flanges are supplied with the fireplace
(found on the fireplace hearth). To level the box and
secure it firmly in place, remove the nailing flanges from
the hearth and install at the sides of the fireplace as
shown in Figure 15.
Installing Outside Air Kit
An outside air damper assembly is installed in all
ODSHR Series Fireplaces. If desired, or if local codes
mandate the use of an air kit, then an AK-MST is
required to complete the installation (from air damper
assembly to the outdoors). If the outside air kit is to be
used, the AK-MST MUST be installed BEFORE the fire-
place is enclosed. Refer to the AK-MST instructions for
field installation. The outside air control lever is located
in the center, just above the left side brick. To 'open',
push contorl lever up and back. To 'close', pull lever
forward and down. (Fig. 16)
FP549
Fig. 15 Fasten fireplace in position.
FP549
9/29/97
BR/BC
Nail Side-
nailing
Flanges
FP557a
SHR
5/11/99 djt
1¹⁄₂"
FP557a
Fig. 14 Safety strip installation.
Metal Safety Strips
(1, 2 or 3 pieces)
"Z" Safety
Strip
(not supplied)
Hearth Ext.
Plat-
form
Fire-
place
1/2" Min.
Overlap
FP710a
SHR OUTSIDE AIR LEVER
WOOD FIREPLACES
10/21/99
Closed
Open
Fig. 16 Outside air operation.
FP710a