Vermont Casting ODSHR42 Outdoor Fireplace User Manual


 
18
ODSHR Outdoor Woodburning Fireplace
20002264
Installing Line for Gas Logs
CFM Corporation fireplaces are designed to accept a
1/2 inch gas line for installation of an approved gas ap-
pliance. (CFM Corporation manufactures a wide variety
of gas logs for use in Majestic Fireplaces units.)
Be sure to have the appliance installed in accordance
with building codes.
Gas connection may enter from either left or right side
of the fireplace.
Locate appropriate gas line in the outer casing of fire-
place and remove insulation from gas line tube. (Fig.
32)
From inside the fireplace, locate the knockout on the
firebrick -- be sure you are on the appropriate or "gas
line" side of the fireplace. Using a flat bladed screw
-
driver or small chisel and hammer, carefully tap around
the knockout until it loosens and falls out.
Install 1/2 inch certified gas pipe through opening.
After gas pipe installation is complete, use insulation
that was removed from gas line tube to repack space
around the pipe. Material should be inserted from
outside of the fireplace and packed tightly to totally seal
between the pipe and tube.
NOTE: Gas pipe should not come in contact with
any wood structures until it has reached a point at
least one (1) inch away from fireplace side.
NOTE: When installing an ANSI Z21.11.2 ventless ap-
pliance, the finishing material used for the mantel must
be rated at 250°F or greater.
FP1172
sealing detail 2
12/20/01 djt
2 x 4 Header
- Do Not Notch at
Ledge Brackets
Fig. 19
Wall Covering
Noncombustible
Decorative Facing
Seal All Cracks
Between Fireplace
Surround and Wall
Materials with
Noncombustible
Material
Noncombustible
Decorative Cover-
ing
Majestic Safety Strips
Must be Overlapped 1/2"
Min.
Seal Crack Between Fire-
place and Hearth Exten-
sion with Noncombustible
Material
FP1172
Fig. 31 Sealing detail.
Hearth
Extension
BTU input of a gas appliance installed in fireplace
should be rated less than 100,000 BTU/Hr.
Gas pipe installation is intended for connection to a
decorative gas appliance only when (1.) incorporating
an automatic shutoff device and (2.) complying with the
Standard for Decorative Gas Appliances for Installa-
tion in Vented Fireplaces (ANSI Z21.60) or CSA draft
requirements for Gas-Fired Log Lighters for Woodburn-
ing Fireplaces (Draft No. 4, August 1993).
Decorative gas appliance should be installed in accor-
dance with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54 (latest edition).
CAUTION: WHEN USING DECORATIVE
GAS APPLIANCE, FLUE DAMPER MUST
BE SET IN FULLY OPEN POSITION. IF YOU
HAVE GLASS DOORS ON THE FIREPLACE,
THEY MUST ALSO BE FULLY OPENED.
WARNING: DO NOT OPERATE AN
UNVENTED GAS LOG SET IN THIS FIRE-
PLACE WITH THE CHIMNEY REMOVED.
WARNING: WHEN INSTALLING AN
UNVENTED GAS LOG SET, THE CFM
CORPORATION MODEL AH3244BK OR
AH3244PB 4" ADJUSTABLE HOOD MUST
BE USED.
OUTSIDE INSTALLATION: ONLY USE THE
OD30CFLN/P VENTED GAS LOG SET.
Only unvented gas log sets which have been found to comply
with the Standard for Unvented Room Heaters, ANSI Z21.11.2,
are to be installed in this fireplace.
If installing an unvented gas log set, refer to statement below:
1"
Min.
FP560SHR
SHR series
5/12/99 djt
1/2"
FP560SHR
Fig. 32 Gas line access.
Hole in Outer
Casing
Gas Line
Tubing
Ceramic
Knockout
Hole in
Outer
Casing
Supply
Line
Repack
Insulation
Ceramic
Knockout
(both sides)