Aussie 6703C8FKK1 Gas Grill User Manual


 
17
7. If “growing” bubbles appear on any of the connection points, you have detected a gas leak. Immediately close the
LP Gas Cylinder valve by turning handle clockwise
a. If leak appears at either end of hose and regulator assembly, retighten the connection at the leak, but do not
over-tighten. (NOTE: Only hand tighten at coupling nut in Fig. 3 shown on previous page) Repeat Leak Test.
b. If the leak is coming from the Gas Cylinder, from the valves at the Control Knobs, or if the leak cannot be
stopped, do not use the grill. Call Customer Service at 1-800-251-7558. Be sure to have the grill model
number and serial number printed on the black label, located inside the left door of the cabinet. If you
need a replacement part under warranty, a proof of purchase will be necessary.
8. Upon completion of leak test, turn all Control Knobs to the “Off” position. Turn the handle on the LP Gas Cylinder
clockwise until it stops. Disconnect LP Gas Cylinder by turning coupling nut on regulator in a counterclockwise
direction until regulator is released from threaded LP Gas Cylinder nozzle.
9. Place the protective cap over LP Gas Cylinder nozzle.
10. Re-attach the wire leads to the Igniter button. Replace Control Panel around flanges at Bowl ends and align bolt
holes on each side. Replace and retighten all bolts. (Fig. 1)
Fig. 6
6. Check for leaks by brushing the soap solution on all gas valves, hose connections and fittings. (Shown by the heavy
arrows in Fig. 4, 5, and 6) Make sure you generously brush the locations with the soap solution, completely sur-
rounding the connections and fittings.
NOTE: After checking the connections and fittings in Figure 4, replace the control panel in the same manner as it was
removed. Take special care to be sure the valve ends are inserted into the openings in the burner ends as shown
in Figure 5a. If all valve ends do not immediately align with the burner end openings, starting at one end, grasp
the tube burner inside the firebox and gently move it until the valve seats in the open end. Also note that the end
caps of the control panel skin fit to the outside of the flanges on the firebox as shown in Figure 5a.
Fig. 5a
Fig. 5