Weber Summit Gas Griill Gas Grill User Manual


 
7
GAS INSTRUCTIONS
CONNECT GAS SUPPLY
a) To connect gas hose supply: Slide back the collar of the quick discon-
nect. Push male fi tting of the hose into the quick disconnect, and maintain
pressure(1). Slide the collar closed(2). If it does not engage or lock, repeat
procedure.
b) To connect gas hose at the Grill: Slide back the collar of the quick dis-
connect. Push male fi tting of the hose into the quick disconnect, and maintain
pressure(1). Slide the collar closed(2). If it does not engage or lock, repeat
procedure.
Gas will not fl ow unless the quick disconnect is properly engaged.
Check for Gas Leaks
ƽ DANGER:
Do not use an open fl ame to check for gas leaks. Be
sure there are no sparks or open fl ames in the area
while you check for leaks. Sparks or fl ames will result
in a fi re or explosion which can cause serious bodily
injury or death and damage to property.
ƽ WARNING: You should check for gas leaks every time
you disconnect and reconnect a gas fi tting.
ƽ WARNING: Perform these leak checks even if your
barbecue was dealer or store assembled.
Turn on gas supply.
Check for leaks by wetting the connections with the soap and water solution
and watching for bubbles. If bubbles form or if a bubble grows, there is a
leak.
Note - Since some leak test solutions, including soap and water, may be
slightly corrosive, all connections should be rinsed with water after checking
for leaks.
ƽ WARNING: Do not ignite burners when leak checking.
(1)
(1)
(2)
(2)
a
b