Weber Genesis Gold C Gas Grill User Manual


 
C-5
Reinstall control panel (after checking for gas
leaks)
(1) Set the control panel in place over both sides of
the frame. Hold the crossover ignition button up
while setting the control panel in place.
(2) Line up the control panel with the white plastic
plugs in the frame brace. Insert screws and tighten
with a Phillips screwdriver until snug. Do not
overtighten.
(3) Push each of the burner control knobs onto their
valve.
(1)
(2)
(3)
(4)
(6)
(5)
ƽ WARNING: Do not ignite burners when leak
checking.
Check for leaks by wetting the connections with the
soap and water solution and watching for bubbles. If
bubbles form or if a bubble grows, there is a leak.
Check:
1) Hose to manifold connection.
ƽ WARNING: If there is a leak at connection (1),
retighten the fitting with a wrench and recheck for
leaks with soap and water solution.
If a leak persists after re-tightening the fitting, turn
OFF the gas. DO NOT OPERATE THE BARBECUE.
Contact the Customer Service Representative in
your region using the contact information sheet
provided with your manual.
2) Regulator to cylinder connection.
3) Manifold to side burner hose connection.
4) Side burner hose to side burner connection.
5) Valves to manifold connections.
6) Hose to regulator connection.
ƽ WARNING: If there is a leak at connections
(2,3,4,5 or 6), turn OFF the gas. DO NOT OPERATE
THE BARBECUE. Contact the Customer Service
Representative in your region using the contact
information sheet provided with your manual.
When leak checks are complete, turn gas supply OFF
at the source and rinse connections with water.