Weber Genesis Gold C Gas Grill User Manual


 
C-4
Connect side burner to manifold
ƽ WARNING: Make sure gas supply is off.
Connect the side burner hose as follows:
1) Slide back the collar of the quick disconnect on the
manifold.
2) Push the male fitting of the side burner hose into
the quick disconnect, and maintain pressure. Slide
the collar closed.
Quick disconnect will be engaged.
Check to be sure the side burner valve is OFF. Push
the side burner control knob down and turn it
clockwise. If it doesnt turn, the valve is OFF. If it does
turn, continue turning it clockwise until it stops, then
the burner valve is OFF.
(1)
(2)
Check for gas leaks
ƽ DANGER
Do not use an open flame to check for gas
leaks. Be sure there are no sparks or open
flames in the area while you check for
leaks. Sparks or open flames will result in
a fire or explosion, which can cause seri-
ous bodily injury or death and damage to
property.
ƽ WARNING: You should check for gas leaks every
time you disconnect and reconnect a gas fitting.
Note - All factory-made connections have been
thoroughly checked for gas leaks. The burners have
been flame-tested. As a safety precaution however,
you should recheck all fittings for leaks before using
your Weber Gas Barbecue. Shipping and handling may
loosen or damage a gas fitting.
ƽ WARNING: Perform these leak checks even if
your barbecue was dealer or store assembled.
You will need: a soap and water solution, and a rag or
brush to apply it.
Note - Since some leak test solutions, including soap
and water, may be slightly corrosive, all connections
should be rinsed with water after checking for leaks.
Make sure side burner is OFF.
Remove the control panel
1) Unscrew the two phillips screws, located on the
right edge of the control panel.
2) Take off the burner control knobs.
3) Lift off the control panel.